Table 1-5. LCD Status Messages

Code

Test

Causes

Corrective Actions

 

 

 

 

E1210

CMOS Batt

CMOS battery is missing,

See "Troubleshooting the

 

 

or the voltage is out of

System Battery" on

 

 

acceptable range.

page 136.

 

 

 

 

E1211

ROMB Batt

RAID battery is either

Reseat the RAID battery

 

 

missing, bad, or unable to

connector. See "Installing a

 

 

recharge due to thermal

RAID Battery" on page 84,

 

 

issues.

and "Troubleshooting the

 

 

 

System Battery" on

 

 

 

page 136.

 

 

 

 

E1229

CPU # VCORE

Processor # VCORE

See "Getting Help" on

 

 

voltage regulator has failed. page 165.

E1310

RPM Fan ##

RPM of specified cooling

See "Troubleshooting

 

 

fan is out of acceptable

System Cooling" on

 

 

operating range.

page 138.

 

 

 

 

E1313

Fan

The system is no longer

Check control panel LCD

 

Redundancy

fan-redundant. Another

for additional scrolling

 

fan failure will put the

messages. See

 

 

 

 

system at risk of

"Troubleshooting System

 

 

overheating.

Cooling" on page 138.

 

 

 

 

E1410

CPU # IERR

Specified microprocessor is

See your system’s

 

 

reporting an internal error.

Information Update Tech

 

 

 

Sheet located on

 

 

 

support.dell.com for the

most current system information. If problem persists, see "Getting Help" on page 165.