Table 1-5. LCD Status Messages
Code | Test | Causes | Corrective Actions |
|
|
|
|
E1210 | CMOS Batt | CMOS battery is missing, | See "Troubleshooting the |
|
| or the voltage is out of | System Battery" on |
|
| acceptable range. | page 136. |
|
|
|
|
E1211 | ROMB Batt | RAID battery is either | Reseat the RAID battery |
|
| missing, bad, or unable to | connector. See "Installing a |
|
| recharge due to thermal | RAID Battery" on page 84, |
|
| issues. | and "Troubleshooting the |
|
|
| System Battery" on |
|
|
| page 136. |
|
|
|
|
E1229 | CPU # VCORE | Processor # VCORE | See "Getting Help" on |
|
| voltage regulator has failed. page 165. | |
E1310 | RPM Fan ## | RPM of specified cooling | See "Troubleshooting |
|
| fan is out of acceptable | System Cooling" on |
|
| operating range. | page 138. |
|
|
|
|
E1313 | Fan | The system is no longer | Check control panel LCD |
| Redundancy | for additional scrolling | |
| fan failure will put the | messages. See | |
|
| ||
|
| system at risk of | "Troubleshooting System |
|
| overheating. | Cooling" on page 138. |
|
|
|
|
E1410 | CPU # IERR | Specified microprocessor is | See your system’s |
|
| reporting an internal error. | Information Update Tech |
|
|
| Sheet located on |
|
|
| support.dell.com for the |
most current system information. If problem persists, see "Getting Help" on page 165.
24