Table 1-6. System Messages
System Message | Corrective Action |
Warning: The current memory configuration is not validated. Change it to the recommended memory configuration or press any key to continue.
This warning message will be displayed when there is no any memory configuration error, but the memory configuration is not recommended by Dell.
Alert! Redundant memory | Redundant memory was set to enabled in |
disabled! Memory | CMOS, but the current configuration |
configuration does not | does not support redundant memory. |
support redundant memory. |
|
Attempting to update Remote | Remote Configuration request has been |
Configuration. Please wait… | detected and is being processed. |
Caution! NVRAM_CLR jumper is | NVRAM_CLR jumper is installed. |
installed on system board | CMOS has been cleared. NVRAM_CLR |
| jumper should be removed. |
CPUs with different cache | The system does not support running |
sizes detected | with processors with mismatched cache |
| sizes |
Decreasing available Memory | One or more DIMMs improperly seated |
| or faulty |
Diskette drive 0 seek failure | Faulty or improperly inserted diskette, |
| incorrect configuration settings in System |
| Setup program, loose diskette/tape drive |
| interface cable, or loose power cable |
| Replace the diskette. |
Diskette read failure | Faulty diskette, faulty or improperly |
| connected diskette/tape drive interface |
| cable, or loose power cable |
Diskette subsystem reset | Faulty diskette/tape drive controller |
failed |
|
Drive not ready | Diskette missing from or improperly |
| inserted in diskette drive |
About Your System