Table 1-6. System Messages

System Message

Corrective Action

Warning: The current memory configuration is not validated. Change it to the recommended memory configuration or press any key to continue.

This warning message will be displayed when there is no any memory configuration error, but the memory configuration is not recommended by Dell.

Alert! Redundant memory

Redundant memory was set to enabled in

disabled! Memory

CMOS, but the current configuration

configuration does not

does not support redundant memory.

support redundant memory.

 

Attempting to update Remote

Remote Configuration request has been

Configuration. Please wait…

detected and is being processed.

Caution! NVRAM_CLR jumper is

NVRAM_CLR jumper is installed.

installed on system board

CMOS has been cleared. NVRAM_CLR

 

jumper should be removed.

CPUs with different cache

The system does not support running

sizes detected

with processors with mismatched cache

 

sizes

Decreasing available Memory

One or more DIMMs improperly seated

 

or faulty

Diskette drive 0 seek failure

Faulty or improperly inserted diskette,

 

incorrect configuration settings in System

 

Setup program, loose diskette/tape drive

 

interface cable, or loose power cable

 

Replace the diskette.

Diskette read failure

Faulty diskette, faulty or improperly

 

connected diskette/tape drive interface

 

cable, or loose power cable

Diskette subsystem reset

Faulty diskette/tape drive controller

failed

 

Drive not ready

Diskette missing from or improperly

 

inserted in diskette drive

About Your System

35

Page 35
Image 35
Dell R900 manual System Messages