Dell R900 manual Removing a Hot-Plug Hard Drive

Models: R900

1 190
Download 190 pages 58.51 Kb
Page 64
Image 64

For 3.5-inch hard drive configurations, the drive blank is keyed to ensure correct insertion into the drive bay. To install a 3.5-inch drive blank, insert and rotate in the keyed side of the blank into the drive bay and press evenly on the other end of the blank until it is fully inserted and latched.

For 2.5-inch hard drive configurations, install the hard drive blank as a 2.5- inch hard drive carrier:

1Open the handle on the drive blank.

2Insert the drive blank into the drive bay until the blank is fully seated.

3Close the handle to lock the blank in place.

Removing a Hot-Plug Hard Drive

NOTICE: To maintain proper system cooling, all empty hard drive bays must have drive blanks installed.

1From the RAID management software, prepare the drive for removal and wait until the hard drive indicators on the drive carrier signal that the drive can be removed safely. See your SAS RAID controller documentation for information about hot-plug drive removal.

If the drive has been online, the green activity/fault indicator will flash as the drive is powered down. When both drive indicators are off, the drive is ready for removal.

2Squeeze the carrier handle to unlatch the carrier from the system.

3Pull the carrier handle away from the system to extract the carrier. See Figure 3-4.

64

Installing System Components

Page 64
Image 64
Dell R900 manual Removing a Hot-Plug Hard Drive