Dell R900 manual Cpu

Models: R900

1 190
Download 190 pages 58.51 Kb
Page 29
Image 29

Table 1-5. LCD Status Messages

Code

Test

Causes

Corrective Actions

E1811 HDD ## Rbld The specified hard drive

Abrt

has experienced a rebuild

abort.

 

See "Troubleshooting a Hard Drive" on page 142. If the problem persists, see your RAID documentation.

E1812

HDD ##

The specified hard drive

Information only.

 

Removed

has been removed from the

 

 

system.

 

 

 

 

 

 

 

 

E1913

CPU &

The BMC firmware does

Update to the latest BMC

 

Firmware

not support the processor.

firmware. See the BMC

 

 

User’s Guide for more

 

Mismatch

 

 

 

information on setup and

 

 

 

 

 

 

use of BMC.

 

 

 

E1A14 SAS Cable A

SAS cable A is missing or

Reseat the cable. If

 

 

bad.

problem persists, replace

 

 

 

cable. See "SAS Controller

 

 

 

Card" on page 78.

 

 

 

E1A15 SAS Cable B

SAS cable B is missing or

Reseat the cable. If

 

 

bad.

problem persists, replace

 

 

 

cable. See "SAS Controller

 

 

 

Card" on page 78.

 

 

 

E2010 No Memory

No memory is installed in

Install memory. See

 

 

the system.

"General Memory Module

 

 

 

Installation Guidelines" on

 

 

 

page 92.

 

 

 

E2011 Mem Config

Memory detected, but is

See "Troubleshooting

 

Error

not configurable. Error

System Memory" on

 

detected during memory

page 139.

 

 

 

 

configuration.

 

 

 

 

E2012 Unusable

Memory is configured, but

See "Troubleshooting

 

Memory

not usable. Memory

System Memory" on

 

subsystem failure.

page 139.

 

 

 

 

 

E2013 Shadow BIOS

The system BIOS failed to

See "Troubleshooting

 

Fail

copy its flash image into

System Memory" on

 

memory.

page 139.

 

 

About Your System

29

Page 29
Image 29
Dell R900 manual Cpu