Table 1-5. LCD Status Messages
Code | Test | Causes | Corrective Actions |
E1811 HDD ## Rbld The specified hard drive
Abrt | has experienced a rebuild | |
abort. | ||
|
See "Troubleshooting a Hard Drive" on page 142. If the problem persists, see your RAID documentation.
E1812 | HDD ## | The specified hard drive | Information only. |
| Removed | has been removed from the |
|
| system. |
| |
|
|
| |
|
|
|
|
E1913 | CPU & | The BMC firmware does | Update to the latest BMC |
| Firmware | not support the processor. | firmware. See the BMC |
|
| User’s Guide for more | |
| Mismatch |
| |
|
| information on setup and | |
|
|
| |
|
|
| use of BMC. |
|
|
| |
E1A14 SAS Cable A | SAS cable A is missing or | Reseat the cable. If | |
|
| bad. | problem persists, replace |
|
|
| cable. See "SAS Controller |
|
|
| Card" on page 78. |
|
|
| |
E1A15 SAS Cable B | SAS cable B is missing or | Reseat the cable. If | |
|
| bad. | problem persists, replace |
|
|
| cable. See "SAS Controller |
|
|
| Card" on page 78. |
|
|
| |
E2010 No Memory | No memory is installed in | Install memory. See | |
|
| the system. | "General Memory Module |
|
|
| Installation Guidelines" on |
|
|
| page 92. |
|
|
| |
E2011 Mem Config | Memory detected, but is | See "Troubleshooting | |
| Error | not configurable. Error | System Memory" on |
| detected during memory | page 139. | |
|
| ||
|
| configuration. |
|
|
|
| |
E2012 Unusable | Memory is configured, but | See "Troubleshooting | |
| Memory | not usable. Memory | System Memory" on |
| subsystem failure. | page 139. | |
|
| ||
|
|
| |
E2013 Shadow BIOS | The system BIOS failed to | See "Troubleshooting | |
| Fail | copy its flash image into | System Memory" on |
| memory. | page 139. | |
|
|
About Your System