Table 1-6. System Messages
System Message | Corrective Action |
|
|
Error: Remote Access | Remote Access Controller initialization |
Controller initialization | failure |
failure |
|
More than one RAC detected, | More than one RAC detected |
system halted |
|
Error 8602 – Auxiliary Device | Mouse cable connector loose or |
Failure | improperly connected, defective mouse |
Verify that mouse and |
|
keyboard are securely |
|
attached to correct |
|
connectors. |
|
Gate A20 failure | Faulty keyboard controller |
General failure | Operating system corrupted or not |
| installed properly |
Keyboard controller failure
Keyboard data line failure
Keyboard stuck key failure
Defective keyboard/mouse controller
Keyboard cable connector loose or improperly connected, defective keyboard, or defective keyboard/mouse controller
Keyboard fuse | has failed. | Overcurrent detected at Keyboard |
|
| connector |
Manufacturing | mode detected | System is in manufacturing mode. Clear |
|
| CMOS via NVRAM_CLR jumper to take |
|
| system out of manufacturing mode. |