Dell R900 manual E2112 Mem Spare Crd # Dimm

Models: R900

1 190
Download 190 pages 58.51 Kb
Page 32
Image 32

Table 1-5. LCD Status Messages

Code

Test

Causes

Corrective Actions

E2112 Mem Spare Crd # DIMM

##

The system BIOS has

See "Troubleshooting

spared the memory

System Memory" on

because it has determined

page 139.

that the memory had too

 

many errors. "## & ##"

 

represents the DIMM pair

 

implicated by the BIOS. If

 

no memory card is present,

 

the "Crd #" string is left

 

out of the message.

 

E2113 Mem Mirror Crd # DIMM ## & ##

The system BIOS has

See "Troubleshooting

disabled memory mirroring

System Memory" on

because it has determined

page 139.

that one half of the mirror

 

has had too many errors.

 

"## & ##" represents the

 

DIMM pair implicated by

 

the BIOS. If no memory

 

card is present, the "Crd #"

 

string is left out of the

 

message.

 

E2118 Fatal NB Mem CRC

One of the connections in

See "Troubleshooting

the Fully Buffered DIMM

System Memory" on

(FBDIMM) memory

page 139.

subsystem link on the

 

Northbound side has

 

failed.

 

E2119 Fatal SB Mem CRC

One of the connections in

See "Troubleshooting

the FBDIMM memory

System Memory" on

subsystem link on the

page 139.

Southbound side has

 

failed.

 

I1910 Intrusion

System cover has been

Information only.

 

removed.

 