Table 1-5. LCD Status Messages
Code | Test | Causes | Corrective Actions |
E2112 Mem Spare Crd # DIMM
##
The system BIOS has | See "Troubleshooting |
spared the memory | System Memory" on |
because it has determined | page 139. |
that the memory had too |
|
many errors. "## & ##" |
|
represents the DIMM pair |
|
implicated by the BIOS. If |
|
no memory card is present, |
|
the "Crd #" string is left |
|
out of the message. |
|
E2113 Mem Mirror Crd # DIMM ## & ##
The system BIOS has | See "Troubleshooting |
disabled memory mirroring | System Memory" on |
because it has determined | page 139. |
that one half of the mirror |
|
has had too many errors. |
|
"## & ##" represents the |
|
DIMM pair implicated by |
|
the BIOS. If no memory |
|
card is present, the "Crd #" |
|
string is left out of the |
|
message. |
|
E2118 Fatal NB Mem CRC
One of the connections in | See "Troubleshooting |
the Fully Buffered DIMM | System Memory" on |
(FBDIMM) memory | page 139. |
subsystem link on the |
|
Northbound side has |
|
failed. |
|
E2119 Fatal SB Mem CRC
One of the connections in | See "Troubleshooting |
the FBDIMM memory | System Memory" on |
subsystem link on the | page 139. |
Southbound side has |
|
failed. |
|
I1910 Intrusion | System cover has been | Information only. |
| removed. |
|
32