HC08 ICS P&E Multilink/Cyclone Pro Connections
Connection Procedure
383
Microcontrollers Debugger Manual
3. The device power selection in the Power/Clock Details area allows the user to specify
whether the target is 2, 3, or 5 Volts, and whether this power is switched/generated by
the P&E interface or if it is separately supplied to the target and under user control. If it
is under user control, the software uses dialog boxes to prompt the user to power the
target up and down when necessary (similar to Class II-IV). See Figure 15.3.
Figure 15.3 Device Power Selection Box
Figure 15.4 M68HC08 Device Clock Selection Box
4. The device clock menu allows two options. See Figure 15.4.
P&E provides clock to target
The device has its own clock
5. Click on Refresh, which detects all P&E devices that are automatically detected, such
as Cyclone Pro USB, Cyclone Pro Ethernet and USB ML MON08 Multilink. See
Figure 15.2.
6. To add a serial/parallel port P&E device such as Cyclone Pro Serial, MON08
Multilink and Cyclone Pro Ethernet (IP outside of subnet mask), proceed to Interface
Selection Manager by pressing the Add A Connection button. For more information
about configuring Cyclone Pro for ethernet operation, see the Cyclone Pro User's
Manual.
7. To remove a manually configured interface, click on Remove Connection button and
choose the interface to be deleted. See Figure 15.5.