HCS08 On-Chip DBG Module
Trigger Module Settings Window
521
Microcontrollers Debugger Manual

Memory Access Triggers

This section describes the various types of Memory Access Triggers available on the on-
chip debug module.
Memory Access at Address A
This mode is used to trigger on a program instruction read and/or write at Address A
memory location.
The code program flow rebuild is displayed in the Trace Component Window
automatically and switched to Instructions Display mode.
Memory Access at Address A or Address B
This mode is used to trigger on a program instruction read and/or write at Address A or at
Address B memory location.
The code program flow rebuild is displayed in the Trace Component Window
automatically and switched to Instructions Display mode.
Memory Access Inside Address A - Address B
Range
This mode is used to trigger on a program instruction read and/or write inside the Address
A - Address B memory range locations.
The code program flow rebuild is displayed in the Trace Component Window and
automatically switched to Instructions Display mode.
Memory Access at Address A then Memory
Access at Address B
This mode is used to trigger on a program instruction sequence first reading and/or writing
at Address A memory location then reading and/or writing at Address B memory location.
The code program flow rebuild is displayed in the Trace Component Window and
automatically switched to Instructions Display mode.