ColdFire On-Chip DBG Module
Trigger Module Settings Window
692
Microcontrollers Debugger Manual

User Triggers mode

When choosing the User Triggers mode, the full strength of the on-chip DBG module can
be exploited in the debugger, providing emulator functionalities.
The A, B and C tabs become accessible to give exact triggering information. Triggers A
and B hardware breakpoints can be set using the Set Trigger button. Refer to HCS08 On-
Chip DBG Module for information about the Browse for Trigger interface.
TIP Trigger A (only) can be adjusted with a mask on the address, that can be set in the
Mask field when the Enable Mask checkbox is set.
The Trace Settings list menu gives a set of options to choose the way the module is going
to start and to stop recording.
Figure 31.6 Trace Settings for User Triggers mode
The Trigger Stop Condition list menu allows you to specify basic sequences and triggers
to pass to break the debugger.