HCS08 On-Chip DBG Module
Context Menu Entries in Source, Data, Assembly and Memory Windows
512
Microcontrollers Debugger Manual

Expert Triggers

The Expert Mode has a different set of triggers and trigger designs. Indeed, to completely
separate the Expert mode from the Automatic mode, the debugger provides a second set of
triggers for the Expert mode. Expert Triggers are independent from the regular triggers
described previously.
Context sensitive context menu entries are slightly different, basically replacing the Set
Trigger Address A entry by a Set DBGCA entry and the Set Trigger Address B entry by a
Set DBGCB entry. The renaming is due to a more physical DBG registers approach in
Expert mode and in the Expert Mode Tab.
Figure 23.9 Source Window Context Menu - Expert Trigger Options
As shown in the next picture, Expert triggers are displayed in Source and Assembly
windows with a small additional “e” character and different colors in the Memory
component.
NOTE When the Expert mode is set, preset Instruction Triggers, Memory Access
Triggers or Capture Triggers designs are grayed out. When the automatic mode
is set or a predefined preset trigger is set, the Expert mode trigger designs are
grayed out.