HCS08 On-Chip DBG Module
Trigger Module Settings Window
529
Microcontrollers Debugger Manual

Trigger Editing

Typically trigger addresses and/or type can be set using context sensitive context menus. It
is also possible to modify trigger addresses and type within the Trigger Module Settings
Window. Pressing Modify Trigger buttons opens a trigger editor dialog box.
Figure 23.30 Browse for Trigger A Dialog Box
In the trigger editor dialog box:
•The Address edit box contains the initial and final trigger address value. This value
can be directly set by typing in the edit box.
•Use the Type list menu to select/change the type of trigger. Use Instruction type for
Instruction Triggers and Read, Write and R/W Access for Memory Access Triggers
and Capture Triggers.
Pressing Modify Trigger in this sub-dialog box modifies and records the trigger in
the trigger database (Trigger Stored as Markpoints).
NOTE Pressing the OK button does NOT update the trigger database. The Modify
Trigger button in the Trigger Module Settings window must be explicitly
pressed before closing the dialog box to update the trigger database.
Pressing Delete Trigger in the dialog box removes the trigger in the trigger database
(Trigger Stored as Markpoints). This trigger address is then considered undefined.