ColdFire V1 Full Chip Simulation Connection
FCS Visualization Utilities
612
Microcontrollers Debugger Manual

The Initialization Step

Initialization requires seven steps. The Function Set instruction must be sent three times
successively to fix the exchange data width, and a fourth time to fix the number of lines
used.
The example shown in Figure 28.35 configures the display module in 8-bit mode, two
lines, with the cursor visible and an increase of AC (the cursor moves to the right).
Figure 28.35 The LCD Display Initialization

LCD Menus

Figure 28.36 shows the LCD menu, which is identical to the context menu. Table 28.6
describes the entry.
Figure 28.36 LCD Menu