5. Function select

5-1 Function select list F:Fundamental Functions

Func

NAME

 

 

LCD Display

 

Setting range

Unit

Min.

Factory setting

Change

User

Remark

No.

 

 

 

Unit

 

 

 

during op

Set value

 

 

 

 

 

 

 

 

 

-30HP

 

40HP-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F00

Data protection

 

 

F00

DATA PRTC

0, 1

 

-

-

 

0

NA

 

 

F01

Frequency command 1

 

 

F01

FREQ CMD 1

0 to 11

 

-

-

 

0

NA

 

 

F02

Operation method

 

 

F02

OPR METHOD

0 to 4

 

-

-

 

0

NA

 

 

F03

Maximum frequency 1

 

 

F03

MAX Hz-1

G11S: 50 to 400Hz

Hz

1

 

60

NA

 

 

 

 

 

 

 

 

P11S: 50 to 120Hz

 

 

 

 

 

 

 

 

F04

Base frequency 1

 

 

F04

BASE Hz-1

G11S: 25 to 400Hz

Hz

1

 

60

NA

 

 

 

 

 

 

 

 

P11S: 25 to 120Hz

 

 

 

 

 

 

 

 

F05

Rated voltage 1

 

 

F05

RATED V-1

0V: (Output voltage

V

1

230:(230V class)

NA

 

 

 

 

(at Base frequency 1)

 

 

proportinal to sorce voltage)

 

 

460:(460V class)

 

 

 

 

 

 

 

 

 

80 to 240V:

(230V class)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

320 to 480V: (460V class)

 

 

 

 

 

 

 

 

F06

Maximum voltage 1

 

 

F06

MAX V-1

80 to 240V:

(230V class)

V

1

230:(230V class)

NA

 

 

 

 

(at Maximum frequency 1)

 

 

320 to 480V: (460V class)

 

 

460:(460V class)

 

 

 

F07

Acceleration time 1

 

 

F07

ACC TIME1

0.01 to 3600s

s

0.01

6.0

 

20.0

A

 

 

F08

Deceleration time 1

 

 

F08

DEC TIME1

 

 

 

 

 

 

 

 

 

 

F09

Torque boost 1

 

 

F09

TRQ BOOST1

0.0, 0.1 to 20.0

-

0.1

G11S:2.0

A

 

 

 

 

 

 

 

 

 

 

 

 

P11S:2.0

 

 

 

F10

Electronic

 

(Select) F10

ELCTRN OL1

0, 1, 2

 

-

-

 

1

A

 

 

F11

thermal 1

 

(Level) F11

OL LEVEL1

INV rated current 20 to 135%

A

0.01

Motor rated current

A

 

 

F12

 

(Thermal time constant) F12

TIME CNST1

0.5 to 75.0 min

min

0.1

5.0

 

10.0

A

 

 

F13

Electronic thermal overload relay

 

F13

DBR OL

G11

[Up to 10[HP]]

-

-

 

 

 

 

 

 

 

 

(for braking resistor)

 

 

 

0, 1, 2

 

 

 

1

A

 

 

 

 

 

 

 

 

 

[15[HP] and above ]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

0

 

 

 

 

 

 

 

 

 

P11

[Up to 15[HP]]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0, 2

 

 

 

0

 

 

 

 

 

 

 

 

 

 

[020[HP] and above ]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

0

 

 

 

F14

Restart mode after

 

 

F14

RESTART

0 to 5

 

-

-

 

0

NA

 

 

 

momentary power failure

 

 

 

 

 

 

 

 

 

 

 

 

 

F15

Frequency limiter

 

(High)

F15

H LIMITER

G11S: 0 to 400Hz

Hz

1

 

70

A

 

 

F16

 

 

(Low)

F16

L LIMITER

P11S: 0 to 120Hz

 

 

 

0

A

 

 

F17

Gain

(for freq. set signal)

F17

FREQ GAIN

0.0 to 200.0%

%

0.1

 

100.0

A

 

 

F18

Bias frequency

 

 

F18

FREQ BIAS

G11S: -400.0 to +400.0Hz

Hz

0.1

 

0.0

A

 

 

 

 

 

 

 

 

P11S: -120.0 to +120.0Hz

 

 

 

 

 

 

 

 

F20

DC brake

 

(Starting freq.) F20

DC BRK Hz

0.0 to 60.0Hz

Hz

0.1

 

0.0

A

 

 

F21

 

 

(Braking level) F21

DC BRK LVL

G11S: 0 to 100%

%

1

 

0

A

 

 

 

 

 

 

 

 

P11S: 0 to 80%

 

 

 

 

 

 

 

 

F22

 

 

(Braking time)

F22

DC BRK t

0.0s(Inactive)

s

0.1

 

0.0

A

 

 

 

 

 

 

 

 

0.1 to 30.0s

 

 

 

 

 

 

 

 

 

F23

Starting frequency

 

(Freq.)

F23

START Hz

0.1 to 60.0Hz

Hz

0.1

 

0.5

NA

 

 

F24

 

 

(Holding time)

F24

HOLDING t

0.0 to 10.0s

 

s

0.1

 

0.0

NA

 

 

F25

Stop frequency

 

 

F25

STOP Hz

0.1 to 60.0Hz

Hz

0.1

 

0.2

NA

 

 

F26

Motor sound

 

(Carrier freq.)

F26

MTR SOUND

0.75 to 15kHz

kHz

1

 

2

A

 

 

F27

 

 

(Sound tone)

F27

SOUND TONE

0 to 3

 

-

-

 

0

A

 

 

F30

FMA

 

(Voltage adjust)

F30

FMA V-ADJ

0 to 200%

 

%

1

 

100

A

 

 

F31

 

 

(Function)

F31

FMA FUNC

0 to 11

 

-

-

 

0

A

 

 

F33

FMP

 

(Pulse rate)

F33

FMP PULSES

300 to 6000p/s (full scale)

p/s

1

 

1440

A

 

 

F34

 

 

(Voltage adjust)

F34

FMP V-ADJ

0%, 1 to 200%

%

1

 

0

A

 

 

F35

 

 

(Function)

F35

FMP FUNC

0 to 10

 

-

-

 

0

A

 

 

F36

30RY operation mode

 

 

F36

30RY MODE

0, 1

 

-

-

 

0

NA

 

 

F40

Torque limiter 1

 

(Driving)

F40

DRV TRQ 1

G11S: 20 to 200%, 999

%

1

 

999

A

 

 

 

 

 

 

 

 

P11S: 20 to 150%, 999

 

 

 

 

 

 

 

 

F41

 

 

(Braking) F41

BRK TRQ 1

G11S: 0%, 20 to 200%, 999

 

 

 

999

A

 

 

 

 

 

 

 

 

P11S: 0%, 20 to 150%, 999

 

 

 

 

 

 

 

 

F42

Torque vector control 1

 

 

F42

TRQVECTOR1

0, 1

 

-

-

 

0

NA

 

 

5-1