E:Extension Terminal Functions

Func

NAME

 

LCD Display

Setting range

Unit

Min.

Factory setting

Change

User

Remark

No.

 

Unit

 

 

 

during op

Set value

 

 

 

 

 

 

 

-30HP

 

40HP-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E01

X1 terminal function

 

E01

X1 FUNC

0 to 35

-

-

 

0

NA

 

 

E02

X2 terminal function

 

E02

X2 FUNC

 

 

 

 

1

NA

 

 

E03

X3 terminal function

 

E03

X3 FUNC

 

 

 

 

2

NA

 

 

E04

X4 terminal function

 

E04

X4 FUNC

 

 

 

 

3

NA

 

 

E05

X5 terminal function

 

E05

X5 FUNC

 

 

 

 

4

NA

 

 

E06

X6 terminal function

 

E06

X6 FUNC

 

 

 

 

5

NA

 

 

E07

X7 terminal function

 

E07

X7 FUNC

 

 

 

 

6

NA

 

 

E08

X8 terminal function

 

E08

X8 FUNC

 

 

 

 

7

NA

 

 

E09

X9 terminal function

 

E09

X9 FUNC

 

 

 

 

8

NA

 

 

E10

Acceleration time 2

 

E10

ACC TIME2

0.01 to 3600s

s

0.01

6.00

 

20.00

A

 

 

E11

Deceleration time 2

 

E11

DEC TIME2

 

 

 

6.00

 

20.00

A

 

 

E12

Acceleration time 3

 

E12

ACC TIME3

 

 

 

6.00

 

20.00

A

 

 

E13

Deceleration time 3

 

E13

DEC TIME3

 

 

 

6.00

 

20.00

A

 

 

E14

Acceleration time 4

 

E14

ACC TIME4

 

 

 

6.00

 

20.00

A

 

 

E15

Deceleration time 4

 

E15

DEC TIME4

 

 

 

6.00

 

20.00

A

 

 

E16

Torque limiter 2

(Driving)

E16

DRV TRQ 2

G11S: 20 to 200%, 999

%

1

 

999

A

 

 

 

 

 

 

 

P11S: 20 to 150%, 999

 

 

 

 

 

 

 

 

E17

 

(Braking)

E17

BRK TRQ 2

G11S: 0%, 20 to 200%, 999

%

1

 

999

A

 

 

 

 

 

 

 

G11S: 0%, 20 to 150%, 999

 

 

 

 

 

 

 

 

E20

Y1 terminal function

 

E20

Y1 FUNC

0 to 37

-

-

 

0

NA

 

 

E21

Y2 terminal function

 

E21

Y2 FUNC

 

 

 

 

1

NA

 

 

E22

Y3 terminal function

 

E22

Y3 FUNC

 

 

 

 

2

NA

 

 

E23

Y4 terminal function

 

E23

Y4 FUNC

 

 

 

 

7

NA

 

 

E24

Y5A, Y5C terminal func.

 

E24

Y5 FUNC

 

 

 

 

10

NA

 

 

E25

Y5 RY operation mode

 

E25

Y5RY MODE

0,1

-

1

 

0

NA

 

 

E30

FAR function

(Hysteresis)

E30

FAR HYSTR

0.0 to 10.0Hz

Hz

0.1

 

2.5

A

 

 

E31

FDT function

(Level) E31

FDT1 LEVEL

G11S: 0 to 400Hz

Hz

1

 

60

A

 

 

 

 

 

 

 

P11S: 0 to 120Hz

 

 

 

 

 

 

 

 

E32

signal

(Hysteresis) E32

FDT1 HYSTR

0.0 to 30.0Hz

Hz

0.1

 

1.0

A

 

 

E33

OL1 function(Mode select)

 

E33

OL1 WARNING

0: Thermal calculation

-

-

 

0

A

 

 

 

 

 

 

 

1: Output current

 

 

 

 

 

 

 

 

E34

signal

(Level) E34

OL1 LEVEL

G11S: 5 to 200%

A

0.01

Motor rated current

A

 

 

 

 

 

 

 

P11S: 5 to 150%

 

 

 

 

 

 

 

 

E35

 

(Timer)

E35

OL1 TIMER

0.0 to 60.0s

s

0.1

 

10.0

A

 

 

E36

FDT2 function

(Level) E36

FDT2 LEVEL

G11S: 0 to 400Hz

Hz

1

 

60

A

 

 

 

 

 

 

 

P11S: 0 to 120Hz

 

 

 

 

 

 

 

 

E37

OL2 function

(Level)

E37

OL2 LEVEL

G11S: 5 to 200%

A

0.01

Motor rated current

A

 

 

 

 

 

 

 

G11S: 5 to 150%

 

 

 

 

 

 

 

 

E40

Display coefficient A

 

E40

COEF A

-999.00 to 999.00

-

0.01

 

0.01

A

 

 

E41

Display coefficient B

 

E41

COEF B

-999.00 to 999.00

-

0.01

 

0.00

A

 

 

E42

LED Display filter

 

E42

DISPLAY FL

0.0 to 5.0s

s

0.1

 

0.5

A

 

 

E43

LED Monitor

(Function)

E43

LED MNTR

0 to 12

-

-

 

0

A

 

 

E44

 

(Display at STOP mode)

E44

LED MNTR2

0, 1

-

-

 

0

A

 

 

E45

LCD Monitor

(Function)

E45

LCD MNTR

0, 1

-

-

 

0

A

 

 

E46

 

(Language)

E46

LANGUAGE

0 to 5

-

-

 

1

A

 

 

E47

 

(Contrast)

E47

CONTRAST

0(soft) to 10(hard)

-

-

 

5

A

 

 

C:Control Functions of Frequency

Func

NAME

 

 

LCD Display

Setting range

Unit

Min.

Factory setting

Change

User

Remark

No.

 

 

Unit

 

 

during op

Set value

 

 

 

 

 

 

 

-30HP

40HP-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C01

Jump frequency

(Jump freq. 1)

C01

JUMP Hz 1

G11S: 0 to 400Hz

Hz

1

 

0

A

 

 

C02

 

(Jump freq. 2)

C02

JUMP Hz 2

P11S0 to 120Hz

 

 

 

0

A

 

 

C03

 

(Jump freq. 3)

C03

JUMP Hz 3

 

 

 

 

0

A

 

 

C04

 

(Hysteresis)

C04

JUMP HYSTR

0 to 30Hz

Hz

1

 

3

A

 

 

C05

Multistep frequency

(Freq. 1)

C05

MULTI Hz-1

G11S: 0.00 to 400.00Hz

Hz

0.01

 

0.00

A

 

 

C06

setting

(Freq. 2)

C06

MULTI Hz-2

P11S: 0.00 to 120.00Hz

 

 

 

0.00

A

 

 

C07

 

(Freq. 3)

C07

MULTI Hz-3

 

 

 

 

0.00

A

 

 

C08

 

(Freq. 4)

C08

MULTI Hz-4

 

 

 

 

0.00

A

 

 

C09

 

(Freq. 5)

C09

MULTI Hz-5

 

 

 

 

0.00

A

 

 

C10

 

(Freq. 6)

C10

MULTI Hz-6

 

 

 

 

0.00

A

 

 

C11

 

(Freq. 7)

C11

MULTI Hz-7

 

 

 

 

0.00

A

 

 

C12

 

(Freq. 8)

C12

MULTI Hz-8

 

 

 

 

0.00

A

 

 

C13

 

(Freq. 9)

C13

MULTI Hz-9

 

 

 

 

0.00

A

 

 

C14

 

(Freq. 10)

C14

MULTI Hz-10

 

 

 

 

0.00

A

 

 

C15

 

(Freq. 11)

C15

MULTI Hz-11

 

 

 

 

0.00

A

 

 

C16

 

(Freq. 12)

C16

MULTI Hz-12

 

 

 

 

0.00

A

 

 

C17

 

(Freq. 13)

C17

MULTI Hz-13

 

 

 

 

0.00

A

 

 

C18

 

(Freq. 14)

C18

MULTI Hz-14

 

 

 

 

0.00

A

 

 

C19

 

(Freq. 15)

C19

MULTI Hz-15

 

 

 

 

0.00

A

 

 

5-2

Page 49
Image 49
Fuji Bikes 5000G11S/P11S instruction manual EExtension Terminal Functions, CControl Functions of Frequency