Data check

(verify)

Error processing

60.00

RUN

PRGPRG MENU

F/D LED SHIFT

PRG

60.00

1.DATA SETTING 2.DATA CHECK 3.OPR MNTR 4.I/O CHECK

5.MAINTENANC 6.LOAD FCTR 7.ALM INF 8.ALM CAUSE 9.DATA COPY

FUNC

DATA

<DATA COPY> 040HP-4

READ

Inverter type of data stored in the keypad

panel

1) Change disabled during operation

If a write operation is attempted during an inverter operation, or vice versa, the error message below will appear.

After stopping the inverter and pressing RESET , retry the write operation.

<DATA COPY> 040HP-4

WRITE INV RUNNING

2) Memory error

If a write operation is attempted while data has not been saved (i.e., no data) in the keypad panel data memory during the read mode, the following error message will appear:

<DATA COPY>

WRITE

MEMORY ERROR

<DATA COPY> 040HP-4

WRITE

3) Verify error

During a data check (verify) operation, if data stored in the keypad panel differs from data stored in the inverter, the following error message is displayed to indicate the function No. The data check is suspended.

To continue the data check and check for other

mismatching data, press FUNCDATA . To stop the data check and switch to another operation, press RESET .

<DATA COPY> 040HP-4

VERIFY Mode (data check)

FUNC

DATA

<DATA COPY> 075HP-4

WRITE

ERR:F25

„„„„

<DATA COPY> 040HP-4

VERIFY

„„„„ Data check in progress

<DATA COPY>

 

040HP-4

 

VERIFY

 

COMPLETE

Data check complete

„„„„„„„„„„„„„„„

 

4) Data protection

When WRITE to the inverter which is protected by "Data protection" function, the following error message will appear. After released the protection, write operation is attempted.

<DATA COPY> 040HP-4

WRITE

DATA PRTCTD

4-14

Page 46
Image 46
Fuji Bikes 5000G11S/P11S instruction manual Change disabled during operation, Memory error, Verify error, Data protection