9-10
Monitoring parameter registers
Address Code Description Unit Range Min. unit Read/
Write
Data
Format
2049 M01 Frequency command
(final command)
- - 2000020000
(max. frequency at ± 20000)
1 R [2]
2053 M05 Frequency command
(final command)
Hz 0.00400.00
(P11S:0.00-120.00)
0.01 R [5]
2054 M06 Actual frequency -
- 2000020000
(max. frequency at ± 20000)
1 R [2]
2055 M07 Actual torque value % - 200.00200.00 0.01 R [6]
2056 M08 Torque current %
- 200.00200.00 0.01 R [6]
2057 M09 Output frequency Hz 0.00400.00
(P11S:0.00-120.00)
0.01 R [5]
2058 M10 Motor output (input
electric power)
% 0.00200.00 0.01 R [5]
2059 M11 Output current r. m. s. % 0.00200.00 (inverter rating
at 100.00)
0.01 R [5]
2060 M12 Output voltage r. m. s. V 0.0600.0 1.0 R [3]
2061 M13 Operation command (final
command)
- Refer to data format [14] - R [14]
2062 M14 Operating state - Refer to data format [16] - R [16]
2063 M15 Universal output terminal
data
- Refer to data format [15] - R [15]
2064 M16 Fault memory 0
2065 M17 Fault memory 1
2066 M18 Fault memory 2
2067 M19 Fault memory 3
- Refer to data format [10] - R [10]
2068 M20 Integrated operating time h
065535 1 R [1]
2069 M21 DC link voltage V 01000 1 R [1]
2071 M23 Type code - Refer to data format [17] - R [17]
2072 M24 Inverter capacity code - Refer to data format [11] - R [11]
2073 M25 ROM version -
064999 1 R [1]
2074 M26 Transmission error
processing code
- Refer to data format [20] - R [20]
2075 M27 Frequency command at
alarm (final command)
- - 2000020000 (max.
frequency at ±20000 )
1 R [2]
2079 M31 Frequency command at
alarm (final command)
Hz 0.00400.00
(P11S:0.00-120.00)
0.01 R [5]
2080 M32 Actual frequency at alarm - - 2000020000
(max. frequency at ± 20000)
1 R [2]
2081 M33 Actual torque at alarm % - 200.00 200.00 0.01 R [6]
2082 M34 Torque current at alarm % - 200.00 200.00 0.01 R [6]
2083 M35 Output frequency at alarm Hz 0.00 400.00
(P11S:0.00-120.00)
0.01 R [5]
2084 M36 Motor output at alarm
(input power)
% 0.00200.00 0.01 R [5]
2085 M37 Output current r.m.s. at
alarm
% 0.00 200.00 (inverter rating
at 100.00)
0.01 R [5]
2086 M38 Output voltage effective
value at alarm
V 0.0 600.0 1.0 R [3]
2087 M39 Operation command at
alarm
- Refer to data format [14] - R [14]
2088 M40 Operating state at alarm - Refer to data format [16] - R [16]
2089 M41 Universal output terminal
data at alarm
- Refer to data format [15] - R [15]
2090 M42 Integrated operation time
at alarm
h 065535 1 R [1]
2091 M43 DC link voltage at alarm V 01000 1 R [1]
2092 M44 Inverter internal air
temp.at alarm
°C0120 1 R [1]
2093 M45 Cooling fin temp. at alarm °C0120 1 R [1]
2094 M46 Life of main circuit
capacitor.
% 0.0100.0 0.1 R [3]
2095 M47 Life of printed circuit
board capacitor.
h 065535 1 R [1]
2096 M48 Life of cooling fan. h 065535 1 R [1]