4-3-6 Checking function data

On the "Program menu" screen, select "2. DATA CHECK". The "Function Select" screen then appears with function codes and names.

60.00

60.00

60.00

60.00

RUN FWD

PRGPRG MENU F/DLED SHIFT

PRG

1.DATA SETTING 2.DATA CHECK 3.OPR MNTR 4.I/O CHECK

FUNC

DATA

F00 0

F01 *1

F02 *1

F03 60Hz

FUNC

DATA

F00 DATA PRTC

0

0 - 1

Function code Data changed from initial value Data

Select the desired function and press FUNCDATA to check the function data. By pressing switches to the "Data setting" screen, to modify data.

FUNC

DATA

, the screen

4-3-7 Monitoring operating status

On the "Program menu" screen, select "3. OPR MNTR" to display the present operating status of inverter. Use and to switch between the four operation monitor screens.

60.00

RUN FWD

PRGPRG MENU F/DLED SHIFT

PRG

60.00

1.DATA SETTING 2.DATA CHECK 3.OPR MNTR 4.I/O CHECK

FUNC

DATA

60.00

Fout=xxxx.xHz Iout= x.xxA Vout= xxxV TRQ= xxx%

Output frequency

Output current

Output voltage

Torque calculation method

60.00

SYN=xxxxxx

LOD=xxxxxx

LIN=xxxxxx

Synchronous rotation speed (r/min)

Load speed (r/min) Line speed (m/min.)

60.00

Fref=xxxx.xHz xxx xx xx xx

Setting frequency

Operation status

FWD/REV: Rotating direction

IL: Current limiting

VL: Voltage limiting

LU: Under voltage

TL: Torque limiting

60.00

SV=xxxxx PV=xxxxx TLD= xxx% TLB= xxx%

PID setting value

PID feedback value

Driving torque limiting setting value Braking torque limiting setting

4-7