C20

JOG frequency

‹This function sets the frequency for jogging operation of motor, which is different from the normal operation.

 

C

2

0

J

 

O

G

 

H

z

 

 

 

 

Setting range

G11S : 0.00 to 400.00 Hz

 

 

 

 

 

P11S : 0.00 to 120.00 Hz

‹Starting with the jogging frequency is combined with jogging select signal input from the keypad panel or control terminal. For details, see the explanations of "E01 Terminal X1" to "E09 Terminal X9."

C21

Pattern operation (mode select)

‹Pattern operation is an automatic operation according to preset operation time, direction of rotation, acceleration and deceleration time, and frequency.

When using this function, set 10 (pattern operation) to "F01 Frequency setting."

The following operation patterns can be selected.

C22

Pattern operation (stage 1)

C28

Pattern operation (stage 7)

‹Seven stages are operated in order (of function codes) according to the values set in "C22 Pattern operation (stage 1)" to "C28 Pattern operation (stage 7)." Each function sets the operation time and the rotating direction for each stage and assigns set values of the acceleration and deceleration time.

C

2

2

S

T

A

G

E

 

1

 

 

 

C

2

3

S

T

A

G

E

 

2

 

 

 

C

2

4

S

T

A

G

E

 

3

 

 

 

C

2

5

S

T

A

G

E

 

4

 

 

 

C

2

6

S

T

A

G

E

 

5

 

 

 

C

2

7

S

T

A

G

E

 

6

 

 

 

C

2

8

S

T

A

G

E

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Related functions

 

 

C

2

1

P

A

T

T

E

R

N

 

 

F01, C30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Set value:10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set value

 

 

 

 

Operation pattern

 

0

Perform a pattern operation cycle, then stop operation.

1

Perform

pattern operation repeatedly. Stop operation

 

using a stop command.

2

Perform

a pattern operation cycle, then continue

 

operation with the last frequency set.

Set or

assign item Operation time

Rotation direction Acceleration and deceleration time

Value range

000 to 6000s

F: Forward (counterclockwise)

R: Reverse (clockwise)

1:Acceleration time 1 (F07), deceleration time 1 (F08)

2:Acceleration time 2 (E10), deceleration time 2 (E11)

3:Acceleration time 3 (E12), deceleration time 3 (E13)

4:Acceleration time 4 (E14), deceleration time 4 (E15)

Note: The operation time is represented by the three most significant digits, hence, can be set with only three

Set value:0

 

Forward

FWD

 

Output frequency 0

Reverse

Set value:1

 

Forward

FWD

 

Output frequency 0

Reverse

End of a cycle

Time

End of a cycle

Time

high-order digits.

‹Setting example 100 F 3

Acceleration and deceleration time (code): 3

Motor rotating direction:

Forward (counterclockwise)

Operation time: 100s

Set the operation time to 0.00 for stages not used, which are skipped in operation.

Set value:2

 

End of a cycle

 

 

FWD

Forward

 

 

 

 

 

Output

 

 

 

frequency

0

 

Time

Reverse

 

 

 

With regard to the set frequency value, the multistep frequency function is assigned as listed in the table below. Set frequencies to "C05 Multistep frequency 1," to "C11 Multistep frequency 7."

Stage No.

Operation frequency to be set

Stage 1

Multistep frequency 1 (C05)

Stage 2

Multistep frequency 2 (C06)

Stage 3

Multistep frequency 3 (C07)

Stage 4

Multistep frequency 4 (C08)

Stage 5

Multistep frequency 5 (C09)

Stage 6

Multistep frequency 6 (C10)

Stage 7

Multistep frequency 7 (C11)

5-29

Page 76
Image 76
Fuji Bikes 5000G11S/P11S instruction manual ‹Setting example 100 F