4-3-3 Switching the LED monitor

On the normal operation, press

 

FUNCDATA

to switch to LED monitor display.

 

 

When power is turned on, the

monitor contents set by the function (E43) are displayed on the LED.

 

 

When stopping

 

 

 

When running

Unit

 

Remarks

 

 

E43

(E44 = 0)

(E44 = 1)

 

(E44 =0,1)

 

 

 

 

 

0

Setting frequency

Output frequency 1

(before slip compensation)

Hz

 

 

 

 

1

Setting frequency

Output frequency 2 (after slip compensation)

 

 

 

 

 

2

Setting frequency

 

 

 

Setting frequency

 

 

 

 

 

3

Output current

 

 

 

Output current

A

 

 

 

 

4

Output voltage

Output voltage (specified value)

V

 

 

 

 

 

(specified value)

 

 

 

 

 

 

 

 

 

 

 

5

Synchronous

 

 

Synchronous speed

r/min.

 

For 4 digits or more, the last

 

 

 

speed setting

 

 

 

 

 

 

 

 

digits are cut, with x10, x100

 

 

 

value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

marked on the indicator.

 

 

6

Line speed setting

 

 

 

 

Line speed

m/min.

 

 

 

 

 

 

 

 

 

 

 

 

value

 

 

 

 

 

 

 

 

 

 

 

7

Load rotation

 

 

Load rotation speed

r/min.

 

 

 

 

 

speed setting

 

 

 

 

 

 

 

 

 

 

 

 

value

 

 

 

 

 

 

 

 

 

 

 

8

Torque calculation

 

 

Torque calculation value

%

 

± indication

 

 

 

value

 

 

 

 

 

 

 

 

 

 

 

9

Power

 

 

Power consumption

kW

 

 

 

 

 

consumption

 

 

 

 

 

 

 

 

 

 

 

10

PID setting value

 

 

 

PID setting value

 

Displayed only when PID is

 

 

11

PID remote setting

 

 

PID remote setting value

 

effective in PID operation

 

 

 

value

 

 

 

 

 

 

 

 

selection.

 

 

12

PID feedback

 

 

PID feedback value

 

 

 

 

 

 

 

 

 

 

value

 

 

 

 

 

 

 

 

 

 

4-3-4 Menu screen

The “Program menu” screen is shown below. Only four items can be displayed simultaneously. Move the cursor with or to select an item, then press FUNCDATA to display the next screen.

1.DATA SETTING 2.DATA CHECK 3.OPR MNTR 4.I/O CHECK 5.MAINTENANC 6.LOAD FCTR 7.ALM INF 8.ALM CAUSE 9.DATA COPY

Display

4.I/O CHECK 5.MAINTENANC 6.LOAD FCTR 7.ALM INF

4-3-5 Setting function data

On the “program menu” screen, select "1. Data Setting" then the “Function Select” screen appears with function codes and names on it. Select the desired function.

60.00

RUN

PRGPRG MENU F/DLED SHIFT

PRG

60.00

1.DATA SETTING 2.DATA CHECK 3.OPR MNTR 4.I/O CHECK

FUNC

DATA

60.00

F00DATA PRTC

F01FREQ COM 1

F02OPR METHOD

F03MAX Hz-1

FUNC

DATA

60.00

F01FREQ COM 1

0

0 11

Function code Function name

Data setting range

Data

4-5