Related functions U08U11, U59

In the following cases, normal life judgment of the capacitor in main circuit may not be able to be performed.

1. When a power is turned off during inverter operation.

2. When cooling fan ON/OFF control is operated. ( function code : H 06= 1)

3.When the power is supplied by the auxiliary input terminals (R0,T0).

4.When the option card is operated .

5.When RS-485 communication is operated .

6.When the power supply is turned off with digital input (FWD, REV, X1-X9) of a control terminal being ON.

In the case of "3", "4", "5" and "6", life judgment is enabled by adjusting the function both code:U08 and U09.

2nd Freq. level detection [FDT2]

This function is same as Frequency detection [FDT1], the detection level of the output frequency and hysteresis width are determined by E36 and E32.

2nd OL level early warning [OL2]

This function outputs an ON signal when the output current exceeds “E37 OL2 LEVEL” for longer than “E35 OL TIMER”.

NOTE) This function is valid for both of Motor 1 and Motor 2.

Terminal C1 off signal [C1OFF]

This function outputs an ON signal when the input current of terminal C1 is less than 2mA.

(When AIO option is connected, it can be detected the disconnection of C2 terminal.)

Synchronization completed by synchronous operation card [SY] Speed agreement signal [DSAG]

PG error signal [PG-ABN]

‹The above functions are set for OPC-G11S-PG / PG2 or PGA. Refer to each instruction manual.

Torque limiting (Signal with delay) [TL2]

‹The turning on signal is output by continuing the limiting action(Torque limit operation, regeneration avoidance operation and overcurrent limiting operation) of 20ms or more.

Settings when shipped from the factory

Digital input

Setting at factory shipment

 

Set value

Description

Terminal Y1

0

Operating [RUN]

Terminal Y2

1

Frequency arrival [FAR]

Terminal Y3

2

Frequency detection [FDT]

Terminal Y4

7

Overload early warning [OL1]

Terminal Y5

10

Ready output [RDY]

E25

Y5 Ry operation mode

‹This function specifies whether to excite the Y5 relay at “ON signal mode” or “OFF signal mode”.

 

E

2

5

Y

5

R

Y

 

M

O

D

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set value

 

 

 

 

 

Operation

0

 

 

At “OFF signal mode”

Y5A - Y5C: OFF

 

 

 

 

 

At “ON signal mode”

Y5A - Y5C: ON

1

 

 

At “OFF signal mode”

Y5A - Y5C: ON

 

 

 

 

 

At “ON signal mode”

Y5A - Y5C: OFF

‹When the set value is "1", contacts Y5A and Y5C are connected when the inverter control voltage is established (about one second after power on).

E30

FAR function signal (Hysteresis)

‹This function adjusts the detection width when the output frequency is the same as the set frequency (operating frequency). The detection width can be adjusted from 0 to ±10 Hz of the setting frequency.

E 3 0 F A R

H Y S T R

Setting range: 0.0 to 10.0 Hz

When the frequency is within the detection width, an ON signal can be selected and output from terminals [Y1] to [Y5].

Output frequency

+Detection width

 

 

 

Set frequency

 

-Detection width

+Detection width

 

 

 

 

Set frequency

 

 

-Detection width

Frequency

 

Time

detection

 

 

signal

 

 

(terminals

ON

ON

Y1 to Y5)

E31

FDT1 function signal (Level)

E32

FDT1 function signal (Hysteresis)

‹This function determines the operation (detection) level of the output frequency and hysteresis width for operation release. When the output frequency exceeds the set operation level, an ON signal can be selected and output from terminals [Y1] to [Y5].

E

3

1

F

D

T

1

L

E

V

E

L

 

E

3

2

F

D

T

 

H

Y

S

T

R

 

Setting range(Operation level) : G11S: 0 to 400 Hz P11S: 0 to 120 Hz

(Hysteresis width) : 0.0 to 30.0 Hz

Output frequency

Set frequency

Hysteresis width

 

 

Operation level

 

Release level

Frequency

 

 

Time

detection

 

 

 

 

signal

 

 

 

 

(terminals

 

ON

 

 

Y1 to Y5)

 

 

 

 

 

 

 

 

 

 

5-25

Page 72
Image 72
Fuji Bikes 5000G11S/P11S instruction manual E25 Y5 Ry operation mode, E30 FAR function signal Hysteresis