The function code consists of alphanumeric characters. Unique alphabetical letters are assigned for each function group.

Table 4-3-1

Function code

Function

Remarks

F00 - F42

Fundamental Functions

 

E01 - E47

Extension Terminal Functions

 

C01 - C33

Control Functions of Frequency

 

P01 - P09

Motor Parameters

 

H03 - H39

High Performance Functions

 

A01 - A18

Alternative Motor Parameters

 

U01 - U61

User Functions

 

o01 - o55

Optional Functions

Can be selected only with an option connected

To scroll “Function Select” screen rapidly , use alphabet.

>> +

>>

or

+

>>

+

to move the screen in a unit grouped by

>> +

F00DATA PRTC

F01FREQ CMD 1

F02OPR METHOD

F03MAX Hz-1

F00DATA PRTC

F01FREQ CMD 1

F02PPR METHOD

F03MAX Hz-1

F42TRQVECTOR1

E01X1 FUNC

E02X2 FUNC

E03X3 FUNC

A18SLIP COMP2

F00DATA PRTC

F01DATA PRTC

F02OPR METHOD

Select the desired function and press

FUNC

DATA

to switch to the “data setting” screen.

On the “data setting” screen, the data values on the LCD can be increased or decreased in the smallest

possible unit by pressing

or

Holding down or expands the rate of change, thereby

enabling values to be modified more rapidly. Otherwise, select the digit to be modified using >> , then set

data directly. When data is modified, the value before modification will be displayed at the same time for

reference purpose. To save the data, press FUNCDATA . Pressing RESET cancels the changes made and

returns to the “Function Select” screen. The modified data will be effective in inverter operation after the data is saved by FUNCDATA . The inverter operation does not change only if data is modified. When data

setting is disabled in the case of “Data protected” or “Data setting invalid during inverter running,” make necessary changes. Data cannot be modified for the following reasons :

Table 4-3-2

Display

Reason for no modification

Release method

 

LINK ACTIVE

Currently writing from RS-485/link

Send a cancel command of function

 

option to Function is being made.

writing from RS-485.

Stops a

 

 

“Write” operation from the link.

NO SIGNAL(WE)

The edit enabling command function

Among functions E01 to E09, turn the

 

is selected using a general-purpose

terminal of data 19 (edit enabling

 

input terminal.

command selection) ON.

 

DATA PRTCTD

Data protection is selected for function

Change function F00 to 0.

 

 

F00.

 

 

INV RUNNING

An attempt is made to change a

Stop inverter operation.

 

 

function that cannot be changed

 

 

 

during inverter operation.

 

 

FWD/REV ON

An attempt is made to change a

Turn FWD/REV command off.

 

function that cannot be changed

 

 

 

with the FWD/REV command on.

 

 

4-6

Page 38
Image 38
Fuji Bikes 5000G11S/P11S To scroll Function Select screen rapidly , use alphabet, To move the screen in a unit grouped by