4-3
Table 4-2-1 Overview of contents displayed for each level
No. Level name Content
1 Operating
mode
This screen is for normal operation. Frequency setting by keypad panel and the
LED monitor switching are possible only when this screen is displayed.
Each function of the keypad panel is displayed in menu form and can be selected.
Selecting the desired function from the list and pressing displays the screen
of the selected function. The following functions are available as keypad panel
functions (menus).
No. Menu
name
Outline
1 DATA SET The code and name of the function are displayed.
Selecting a function displays a data setting screen for
checking, or modifying data.
2 DATA CHECK The code and name of the function are displayed. Select
a function to display a screen for checking data. Modifying
data is possible as described above by going to the data
setting screen.
3 OPR MNTR Can check various data on the operating status.
4 I/O CHECK Can check the status of analog and digital input/output for
the inverter and options as an I/O checker.
5 MAINTENANC Can check inverter status, life expectancy , communication
error status, and ROM version information as maintenance
information.
6 LOAD FCTR Can measure maximum and average current and average
breaking force in load rate measurement.
7 ALM INF Can check the operating status and input/output status at
the latest alarm occurrence.
8 ALM CAUSE Can check the latest alarm or simultaneously occurred alarms
and alarm history. Selecting the alarm and pressing ,
displays the contents of alarm as troubleshooting.
9 DATA COPY Places the function of one inverter in memory for copying to
another inverter.
2 Program
menu
3 Screen for
each function
The function screen selected on the program menu appears, hence completing
the function.
4 Supplementary
screen
Functions not completed (e.g., modifying function data, displaying alarm factors)
on individual function screens are displayed on the supplementary screen.
FUNC
DATA
FUNC
DATA