Table 4-2-1 Overview of contents displayed for each level

No. Level name

1Operating mode

2Program menu

3Screen for each function

4Supplementary screen

Content

This screen is for normal operation. Frequency setting by keypad panel and the LED monitor switching are possible only when this screen is displayed.

Each function of the keypad panel is displayed in menu form and can be selected.

Selecting the desired function from the list and pressing FUNCDATA displays the screen of the selected function. The following functions are available as keypad panel functions (menus).

No.

Menu

Outline

 

 

 

name

 

 

 

1

DATA SET

The code and name of the function are displayed.

 

 

Selecting a function displays a data setting screen for

 

 

checking, or modifying data.

 

 

2

DATA CHECK

The code and name of the function are displayed.

Select

 

 

a function to display a screen for checking data. Modifying

 

 

data is possible as described above by going to the data

 

 

setting screen.

 

 

3

OPR MNTR

Can check various data on the operating status.

 

 

4

I/O CHECK

Can check the status of analog and digital input/output for

 

 

the inverter and options as an I/O checker.

 

 

5

MAINTENANC

Can check inverter status, life expectancy , communication

 

 

error status, and ROM version information as maintenance

 

 

information.

 

 

6

LOAD FCTR

Can measure maximum and average current and average

 

 

breaking force in load rate measurement.

 

 

7

ALM INF

Can check the operating status and input/output status at

 

 

the latest alarm occurrence.

 

 

8

ALM CAUSE

Can check the latest alarm or simultaneously occurred alarms

 

 

and alarm history. Selecting the alarm and pressing

FUNCDATA

,

 

 

displays the contents of alarm as troubleshooting.

 

 

 

 

 

 

9

DATA COPY

Places the function of one inverter in memory for copying to

 

 

another inverter.

 

 

The function screen selected on the program menu appears, hence completing the function.

Functions not completed (e.g., modifying function data, displaying alarm factors) on individual function screens are displayed on the supplementary screen.

4-3

Page 35
Image 35
Fuji Bikes 5000G11S/P11S instruction manual Overview of contents displayed for each level