Fuji Bikes 5000G11S/P11S instruction manual Slippage = Synchronous speed-Rated speed

Models: 5000G11S/P11S

1 132
Download 132 pages 56.51 Kb
Page 89
Image 89

Motor 2 (A:Altemative Motor Parameters)

A01

Maximum frequency2

‹This function sets the maximum frequency for motor 2 output by the inverter. This function operates the same as "F03 Maximum frequency 1." For details, see the explanation for F03.

A

0

1

M

A

X

 

H

z

-

2

 

 

A02

Base frequency 2

‹This function sets the maximum output frequency in the constant-torque area of motor 2 (i.e., output frequency at rated output voltage). This function operates the same as "F04 Base frequency 1." For details, see the explanation for F04.

A

0

2

B

A

S

E

 

H

z

-

2

 

A11

Motor 2 (Capacity)

‹This function sets the capacity of motor 2. This function operates the same as "P02 Motor 1 (Capacity)." For details, see the explanation for P02. However, the related motor data functions change to "A12 Motor 2 (Rated current)," "A15 Motor 2 (No-load current)," "A16 Motor 2 (%R1 setting)," and "A17 Motor 2 (%X setting)."

A 1 1 M 2 - C A P

A12

Motor 2 (Rated current)

‹This function sets the rated current of motor 2. This function operates the same as "P03 Motor 1 (Rated current)." For details, see the explanation for P03.

A 1 2 M 2 - I r

A03

Rated voltage 2

‹This function sets the rated value of voltage output to motor 2. This function operates the same as "F05 Rated voltage 1." For details, see the explanation for F05.

 

A

0

3

R

A

T

E

D

 

V

2

 

 

A04

 

 

 

Maximum voltage 2

‹This function sets the maximum value of the inverter output voltage of motor 2. This function operates the same as "F06 Maximum voltage 1." For details, see the explanation for F06.

 

A

M

A

X

 

V

-

2

 

 

 

A05

 

 

 

Torque boost 2

‹This function sets the torque boost function of motor 2. This function operates the same as "F09 Torque boost 1." For details, see the explanation for F09.

A

0

5

T

R

Q

 

B

O

O

S

T

2

A06 Electronic thermal overload relay 2 (Select)

A07 Electronic thermal overload relay 2 (Level)

A08 Electronic thermal overload relay 2 (Thermal time constant)

‹This function sets the function of the electronic thermal overload relay for motor 2. This function operates the same as F10 to F12, "Electronic thermal overload relay 1." For details, see the explanations for F10 to F12.

A

0

6

E

L

C

T

R

N

 

O

L

2

A

0

7

O

L

 

 

L

E

V

E

L

2

 

A

0

8

T

I

M

E

 

C

N

S

T

2

A09

 

 

 

Torque vector control 2

‹This function sets the torque vector function of motor 2. This function operates the same as "F42 Torque vector control 1." For details, see the explanation for F42.

A 0 9 T R Q V E C T O R 2

A13

Motor 2 (Tuning)

‹This function sets the auto tuning of motor 2. This function operates the same as "P04 Motor 1 (Tuning)." For details, see the explanation for P04.

 

A

1

3

M

2

 

T

U

N

1

 

 

 

A14

 

 

Motor 2 (On-line tuning)

‹This function sets the online tuning of motor 2. This function operates the same as "P05 Motor 1 (On-line tuning)." For details, see the explanation for P05.

 

A

1

4

M

2

 

T

U

N

2

 

 

 

A15

 

Motor 2 (No-load current)

‹This function sets the no-load current of motor 2. This function operates the same as "P06 Motor 1 (No-load current)." For details, see the explanation for P06.

 

A

1

5

M

2

-

I

 

o

 

 

 

 

 

A16

 

 

Motor 2 (%R1 setting)

A17

 

 

Motor

2 (%X setting)

‹This function sets %R1 and %X of motor 2. This function operates the same as "P07 Motor 1 (%R1 setting)," and "P08 Motor 1 (%X setting)." For details, see the explanations for P07 and P08.

 

 

M

 

2

-

%

R

1

 

 

 

 

 

 

M

 

2

-

%

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A18

Slip compensation control 2

‹This function sets the amount of slip compensation for motor 2. This function operates the same as "P09 Slip compensation control." For details, see the explanation for P09.

A

1

8

S

L

I

P

 

C

O

M

P

2

Set value : 0.00Hz to 15.00Hz

‹Calculate the amount of slip compensation using the following formula:

Slip compenssation amount

A10

Number of motor-2 poles

= Base frequency⋅

Slippage[r / min]

Hz

 

‹This function sets the number of poles of motor 2 to be

 

Synchronous speed [r / min]

driven.

This function operates the same as "P01 Number

Slippage = Synchronous speed-Rated speed

 

of motor-1 poles." For details, see the explanation for P01.

A 1 0 M 2

P O L E S

5-42

Page 89
Image 89
Fuji Bikes 5000G11S/P11S instruction manual Slippage = Synchronous speed-Rated speed