Chapter 8 Complete Command List

Miscellaneous Commands

These commands do not fall under any specific section of the command shell but they are used quite frequently.

save [default]

Save the current settings to flash memory so they are available after power cycles. Sysinfo, destination, model, logpath, variable, user, and I/O port settings will be saved. If default is specified as well, factory settings will be saved, overwriting any new settings you have configured.

reset

Perform a warm boot or hardware reset simulating a power-on reset. Restores current settings to those stored in flash memory since the flash memory settings will be read and loaded into memory upon bootup.

load [default]

Load the settings stored in flash memory and use them as the current or working settings. If default is specified as well, factory settings will be loaded.

lpstat [ioport] [jobID]

lpstat prn

Display active and queued jobs and I/O port status for a given ioport or jobID. Specifying one of these parameters will shorten the output focusing on the particular I/O port or print job specified.

cancel jobID

cancel d1prn-10

Remove a job from an I/O port queue. Use “lpstat” to find a particular job ID first.