Page 48
Image 48

ARENA / RANGER

USER GUIDE

5.Under Outgoing Connection to Remote Site do the following:

a.Check Enable if you want to use ARENA for dialing-in to a remote site.

b.Uncheck Enable if ARENA is only used for receiving alarms.

Example:

If you have a scenario where one ARENA runs in the office to receive alarms while another ARENA runs on your notebook which you use only for dialing- in, choose the following setup:

Uncheck Enable in the ARENA running in the office, because this is the one used as alarm recipient. Check Enable in the ARENA, running on your notebook, because this is the one used only for dialing-in to the remote site. iLON 10 and incoming connection settings will become read-only in this case.

NOTES:

Only one ARENA can be connected to an iLON 10 on the same site.

You must configure the iLON 10 in the ARENA that is used as alarm recipient.

When restarting the ARENA Service (see “ARENA Application” section), all iLON 10 will be automatically connected, independent of the Enable setting.

c.Select Static IP if the connection is established using static IP addressing.

d.Select URL (Use this if iLON 10 is configured for DHCP) if dynamic IP addressing is used by the iLON 10.

e.If Static IP has been selected, enter the IP address in Remote Site URL or IP Address, the subnet mask in Subnet Mask and the gateway address in Gateway Address. Make sure that this is a valid IP address which can be reached from the supervisor ARENA. The default IP address is 192.168.1.222. If you do not know which IP address to use, contact the I.T. administrator of the remote site (see also Incoming Connection from Remote Site settings). The subnet mask is used to define the subnet in which the iLON 10 resides. In the iLON 10 configuration (section "General"), this setting will be stored as subnet mask. The gateway address is the IP address of the gateway which iLON 10 uses to contact the supervisor ARENA. Used in LAN scenarios to resolve addressing if iLON 10 and the supervisor PC are in different subnets. Contact the I.T. administrator to get the gateway’s IP address.

f.If URL (Use this if iLON 10 is configured for DHCP) has been selected, enter the URL or the IP address in Remote Site URL or IP Address.

6.Under Incoming Connection from Remote Site, do the following: