Table | Mopier Messages, continued |
| |
| |||
If the following errors persist, call your | |||
|
|
|
|
Message |
| Description | Recommended Action |
|
|
| |
22 PARALLEL IO ERROR | For | Press [Select[*] to clear the | |
CHECK SETUP |
| configuration, the computer and | error message (data will be |
|
| mopier are not communicating | lost). If the error continues, call |
|
| because of improper signal | your authorized HP dealer or |
|
| protocols. Check both computer | service representative. |
|
| and mopier I/O settings. |
|
|
|
| |
22 HP MIO 1 IO ERROR | For the MIO error, this is an I/O | For the parallel configuration, | |
CHECK SETUP (or HP | buffer overrun error. | check for loose cable; use a | |
MIO 2) |
|
| |
|
|
| Chapter 1 for HP cable part |
|
|
| numbers and information). |
|
|
| (Note: some |
|
|
| cables may be missing pin |
|
|
| connections.) |
|
|
| If you are using an I/O other |
|
|
| than the |
|
|
| see the manual for that device |
|
|
| or contact your dealer. If you |
|
|
| are on a network, contact your |
|
|
| network administrator. |
|
|
| If problem persists, |
|
|
| |
|
|
| error messages are saved in the |
|
|
| Error Log. |
|
|
|
|
30.x.y DISK |
| The mopier hard disk is not | Press [Select[*] to continue. |
NOT INITIALIZED |
| initialized. | Use the Windows based HP |
|
|
| JetAdmin utility or the |
|
|
| Macintosh based HP LaserJet |
|
|
| Utility to initialize the disk. |
|
|
|
|
30.x.y DISK |
| The mopier hard disk has failed | Press [Select[*] to continue. |
FAILURE |
| self test. | Turn power off and verify that |
|
|
| the ribbon cable that connects |
|
|
| the disk to the mopier is |
|
|
| securely fastened. If the |
|
|
| control panel message |
|
|
| continues to be displayed, the |
|
|
| disk drive needs to be |
|
|
| replaced. |
|
|
|
|
Continued on the next page.