Calibrating the Media Thickness Sensor

1.Verify the carriage head height and calibrate the head height if needed.

2.From the Front Page, select Calibrations > Service Cali- brations > Media Thickness Sensor Calibration.

If you already entered this calibration from the previous calibration, skip this step and go to the next step.

3.Press ! (Proceed).

The control panel will report the current sensor reading and the optimal range.

4.Press ! (Proceed).

The control panel prompts you to remove media if any media is loaded.

5.After unloading any media, press ! (Proceed).

The printer raises the rail to its home position, then tests the sensor. If the thickness sensor needs to be adjusted, the control panel prompts you to adjust it.

6.To adjust the sensor position, loosen both nuts that secure the sensor beneath the rail.

Fig. 4-8. Media thickness sensor (brushes removed for clarity,

not necessary to perform procedure)