North America: If your building receives power from a standard three-phase supply, note that the printer will use only two of the three phases. This means that your building’s three-phase power transformer may have an unbalanced load. Check with your electrician to verify that your building has sufficient capacity for this unbalanced load.

Optional Auxiliary Power for Vacuum/Pressure System:

A 24 volt DC power supply with universal adapters is included with the printer. It can be connected from the 24 VDC jack on the rear of the printer to either of two options:

UPS — customer-supplied uninterruptible power supply, out- put 100-240 VAC, 50/60 Hz, minimum of 15 watts of power, provides battery backup to the vacuum system in the event of a power failure.

Wall outlet — 100-240 VAC, 50/60 Hz, provides temporary power to the vacuum system when it is necessary to power down the printer for service.

Use of the auxiliary power supply is optional, but if power is unexpectedly removed from the printer, printhead vacuum will be lost and ink will leak from the printheads. The amount of ink lost will be limited to the ink currently in the printheads, not the ink in the ink supply boxes which as not yet been pumped to the printheads.

Required power cord (supplied with printer):

North American (UL/CSA approved), length 8.2 feet (2.5 m),

OR

European (Harmonized), length 8.2 feet (2.5 m)

A-4

Specifications

Page 110
Image 110