Auto Calibrations

The printer’s piezo printheads are aligned at the factory. Head and bidirectional calibrations should be necessary only rarely (for example, when the heads have been moved within the carriage or replaced).

1.Press the Calibrate key from the Front Page screen, then press Auto Calibrations in the menu.

2.Select one of the Auto Calibrations.

AutoBiDi (bidirectional) Calibration — ensures that every working jet fires at precisely the same location (regardless of the carriage direction of travel).

AutoH2H (head-to-head) Calibration ensures that the printheads are in alignment relative to each other.

AutoJet Calibration — locates and substitutes missing jets for working jets. This is the same calibration per- formed as when you press the AutoJet button on the Front Page screen (see “AutoJet” on page 4-3).

Full AutoSet — runs all three calibrations in sequence. The printer prints a test pattern then reads it and makes The necessary adjustments or jet substitutions. After completing the calibration(s), a report is printed that shows:

Calibration results — a summary such as SUCCESS- FUL CALIBRATION or an error message

Header showing the date and time, software version, and printer type

Calibration detail — the calibration data for each head. The AutoJet detail reports how many jets were mapped out by AutoJet, how many are permanently mapped out by the operator, and whether the head is usable (from a jetout standpoint) in the various print modes. The higher quality modes (Production and High Quality) use jet replacement, so they can print successfully with a greater number of jets out than can Billboard mode.

AutoSet Summary — when enabled, a table of the results of the Full AutoSet calibration is printed after the AutoSet test patterns. When you enable the AutoSet Summary, you can show or hide the detailed calibration data.

4-6

Auto Calibrations