Print Jet-Out LinesDefault Registration Data

Press No to clear the soft bad jets only.

Press Yes to clear both the hard and soft jets. The control panel displays this message:

All reported bad jets have been cleared.

25.Press ! (Proceed).

When you have finished mapping jets, the following sum- mary appears on the control panel:

xsoft jets currently reported bad.

xhard jets currently reported bad. x new soft bad jets reported. x new hard bad jets reported.

xprevious soft bad jets cleared.

xprevious hard bad jets cleared.

where x is the number of jets.

This option prints a version of the Prime Bars in which missing jets that are replaced are marked with a black square.

This option resets all registration data. Since there is no registration data after running this option, all calibration values must be reestablished by running the calibrations.

Manual Calibrations

4-23