Manual Calibrations — allows you to calibrate the printer visually, without the printer’s digital imaging sensor. Inaccu- rate judgments by the operator during these tests could result in substandard output. See “Manual Calibrations” on page 4-8for instructions.

Service Calibrations — enables you to perform three ser- vice calibrations: Head Height, Media Thickness Sensor, Service Station. For best results, perform these three cali- brations in this order. See “Service Calibrations” on page 4- 25 for instructions.

AutoTune (roll-fed media only) — schedules jet mainte- nance to run automatically after a certain number of prints have printed. See “AutoTune” on page 4-4for instructions.

Calibration Summary — prints summary information with the AutoSet calibration test patterns, or transmits registra- tion or jet data to a log file on the print server.

Configure for Profile Creation (cut sheet printing only) — causes all calibration prints to print on the same cut sheet, rather than ejecting the sheet after each calibration print.

Automatically disabled after all calibration prints are fin- ished, when a print job is received from the RIP, or when roll-fed media is loaded. The user can specify a dry time delay after which the linearization will begin.

Printer Settings To display this menu, press the Settings button on the Front Page screen. Printer Settings enables you to set many options that control how the printer operates. Settings saved by the Media Wizard are indicated by MEDIA WIZARD in the margin.

MEDIA WIZARD

Platen Vacuum Control — turns on the vacuum fans, then

 

allows you to raise or lower the fan speed. Raise the speed if

 

the media is warped and rising off the platen, lower the

 

speed if the media is buckling or wrinkling. Turn off the vac-

 

uum fans for lightweight media.

 

Optionally, you can enable Leading Edge Static Control to

 

reduce overspray in areas of fine text at the leading edge of

 

a rigid media print. This lowers the platen vacuum level until

 

the leading edge of the media has passed over the front

 

edge of the platen. Disable if the media needs full vacuum

 

for good media feed.

3-8

Menus