C Data Fields Sent from the Utility Meter to HP

All usage data sent to HP from the customer device is encrypted using either HTTPS SSL with 1024–bit keys or encrypted e-mail. The following tables are helpful if you want to compare your usage data at the Utility Pricing Solutions Web portal, http://www.hp.com/go/payperuse.

PPU Partition Usage Data Fields Sent from the Utility Meter to HP shows the PPU partition data fields that are transmitted from the Utility Meter to HP.

Table C-1 PPU Partition Usage Data Fields Sent from the Utility Meter to HP

Usage Data Field

Description

CPUID

CPU ID

CPUSpeed

CPU speed

CPUType

The number or string representing the CPU family (PA-RISC,

 

Integrity)

ID

Hard partition ID.

IsActive

Is the PPU partition active? (true/false)

IsHardPartitioned

Is the PPU device hard partitioned? (true/false)

IsHPVirtualMachinesHost

Is Virtual Machine Host (true/false)

IsVirtualPartition

Is the PPU partition a virtual partition? (true/false)

LocalID

Local ID

LocalSampleStartTime

Local sample start time

NumActiveCPUs

Number of active CPUs

NumCPUs

Number CPUs

NumFreeCPUs

The number of CPUs not allocated to a partition.

NumHardPartitions

Number of hard partitions configured in the complex.

OSType

Supported operating systems for PPU: HP-UX, OpenVMS, or

 

Windows Server 2003

OSVersion

Version of the OS running on the PPU partition

PercentCPUUsage

Percent CPU usage

ProductNumber

Model number of the hardware platform on which the PPU partition

 

is running

ReportType

Type of report sent

ReportVersion

Report version

SampleDuration

Sample suration

SerialNumber

System serial number of the PPU server

SystemIdentifier

The hostname or Fully Qualified Domain Name (FQDN)

Timezone

Time zone

TotalCPUs

Number of CPUs being metered

TotalNumCPUs

Total number of CPUs

UniqueIdentifier

A string based on the hardware system identifier of the PPU

 

partition being metered

UpdateTimestamp

Update timestamp

UTCSampleStartTime

UTC sample start time

101

Page 101
Image 101
HP Pay per use (PPU) manual Data Fields Sent from the Utility Meter to HP, Cpuid