You should see the T2805AA product and its version displayed:

#Initializing...

#Contacting target "mysystem"...

#Target: mysystem:/

#

 

 

# T2805AA

8.13

HP Utility Pricing Metering Software

T2805AA.UPS-Meter

8.13

HP Utility Pricing Metering Software

#

 

 

If T2805AA is not installed, install the software as described in Chapter 2: “Installing and Configuring the Utility Meter Software”.

2.If the Utility Meter software is installed, execute the following command and verify the correct output:

# /opt/meter/bin/monitor status

You should see output similar to:

Status:

tnameserv...running, pid=11945, responding das_SERVER...running, pid=11953, collecting transporter...running, pid=11968 monitor...running, pid=10536 wbem...running

http...running

All processes and services should be running. (Note that process ID numbers will be different on your machine.) If there are any processes or services that are not running, stop and restart the Utility Meter application by executing the following commands as root on the Utility Meter:

a.# /opt/meter/bin/monitor stop

b.# /opt/meter/bin/monitor start

You can verify proper operation of the Utility Meter software by performing Step 2 again.

4.3 Verifying the Correct Version of HP SIM is Installed

The Utility Meter software is dependent on the HP Systems Insight Manager (HP SIM) version 5.1 software to be installed on the Utility Meter.

Perform the following procedure on the Utility Meter to verify that version 5.1 of HP SIM is installed. On the Utility Meter:

1.Log in as root.

2.Execute the following command:

# /usr/sbin/swlist /usr/bin/grep -i sim

You should output that is similar to the following displayed:

HPSIM-HP-UX

C.05.01.00.01.13 HP Systems Insight Manager Server Bundle

If you do not see version 5.1 of HP SIM displayed, install the HP SIM software by following the instructions in Installing the HP Systems Insight Manager Software.

If you see the correct version of HP SIM displayed, then you have successfully verified that the correct version of HP SIM is installed and no further action is necessary.

4.4 Verifying the CIM Server Software Is Operational

Proper operation of the CIM server on the Utility Meter is required for both Pay per use (PPU) and Utility Ready Storage (URS) EVA data collection.

Execute the following command on the Utility Meter to verify that the CIM server software is running correctly:

78 Verifying Utility Meter Operation