4069-XXX
| FRU | Action |
|
|
|
1 | Erase Lamp/Lens | Check the erase lamp lens for any |
| Assembly (models 010/ | signs of toner, paper dust or other |
| 212/414/616) | types of contamination. Clean the |
|
| lens with a soft dry cloth if |
|
| necessary. If unable to clean the |
|
| contamination off the lens, replace |
|
| the lens and lamp assembly. Check |
|
| the erase lamp assembly. Use the |
|
| same procedure as outlined in the |
|
| “Erase Lamp Service Check (010/ |
|
| 212/414/616)” on page |
|
|
|
2 | Printhead | The printhead on the Optra T |
|
| printers cannot be cleaned. Try |
|
| another printhead if all other |
|
| attempts fail to correct a background |
|
| problem. |
|
|
|
3 | Transfer Roll Assembly | Check the high voltage contact from |
|
| the HVPS to the transfer roll. Check |
|
| the transfer arm assembly right side |
|
| bearing for any signs of |
|
| contamination, pitting or a loose |
|
| cable to the bearing. If any problems |
|
| are found, replace the defective part. |
|
| Check the transfer roll shaft for any |
|
| signs of contamination, wear or |
|
| pitting on the ends of the shaft that |
|
| go into the bearings. If a problem is |
|
| found, clean the ends of the shaft or |
|
| replace the transfer roll assembly. |
|
|
|
4 | High Voltage Contacts | Check the high voltage contacts on |
|
| the right side frame to ensure they |
|
| are clean and not bent, deformed, or |
|
| pitted. If incorrect, replace the |
|
| contact. |
|
|
|