4069-XXX

 

FRU

Action

 

 

 

1

Erase Lamp/Lens

Check the erase lamp lens for any

 

Assembly (models 010/

signs of toner, paper dust or other

 

212/414/616)

types of contamination. Clean the

 

 

lens with a soft dry cloth if

 

 

necessary. If unable to clean the

 

 

contamination off the lens, replace

 

 

the lens and lamp assembly. Check

 

 

the erase lamp assembly. Use the

 

 

same procedure as outlined in the

 

 

“Erase Lamp Service Check (010/

 

 

212/414/616)” on page 2-45.

 

 

 

2

Printhead

The printhead on the Optra T

 

 

printers cannot be cleaned. Try

 

 

another printhead if all other

 

 

attempts fail to correct a background

 

 

problem.

 

 

 

3

Transfer Roll Assembly

Check the high voltage contact from

 

 

the HVPS to the transfer roll. Check

 

 

the transfer arm assembly right side

 

 

bearing for any signs of

 

 

contamination, pitting or a loose

 

 

cable to the bearing. If any problems

 

 

are found, replace the defective part.

 

 

Check the transfer roll shaft for any

 

 

signs of contamination, wear or

 

 

pitting on the ends of the shaft that

 

 

go into the bearings. If a problem is

 

 

found, clean the ends of the shaft or

 

 

replace the transfer roll assembly.

 

 

 

4

High Voltage Contacts

Check the high voltage contacts on

 

 

the right side frame to ensure they

 

 

are clean and not bent, deformed, or

 

 

pitted. If incorrect, replace the

 

 

contact.

 

 

 

2-98Service Manual

Page 126
Image 126
Lexmark 4069-XXX manual Erase Lamp Service Check