4069-XXX

Dead Machine Service Check

Note: If a high capacity input tray is installed, remove the option and check the base printer for correct operation. If the base printer operates correctly, go to “High Capacity Feeder Input Tray Service Check” on page 2-55. If the base printer continues to not operate correctly, remove any other attached paper handling options. Observe all necessary ESD precautions when removing and handling the controller board, engine board or any of the installed option cards or assemblies.

Service Tip: When removing the LVPS from the printer observe the following:

1.The LVPS uses a self docking connector that mates with another connector mounted on the left side frame assembly. Some force may be required to pull the LVPS loose from the connector.

2.Gently remove the LVPS supply using caution not to damage the printed circuit board. Pull the LVPS out far enough to reach the fuser lamp cable.

3.The fuser lamp cable uses a locking type of connector system. Unlock the fuser lamp cable connector, disconnect the cable and remove the LVPS from the printer.

Note: If the LVPS is blowing fuses, remove the LVPS from the printer. Check the metal LVPS shield for signs of damage that causes the shield to touch components on the LVPS board assembly.

 

FRU

Action

 

 

 

1

Line Voltage

Check the AC line voltage. If the line

 

 

voltage is incorrect, inform the

 

 

customer.

 

 

 

2

AC Line Cord

Check the line cord for any signs of

 

 

damage. If correct, check the

 

 

continuity of the line cord and

 

 

replace if necessary.

 

 

 

2-32Service Manual

Page 60
Image 60
Lexmark 4069-XXX manual Dead Machine Service Check