4069-XXX
Fuser Narrow Media Sensor/Flag Assembly
1.Remove the fuser assembly.
2.Remove the exit roll assembly.
3.Remove the fuser board cover.
4.Disconnect the sensors from the fuser board.
5.Remove the lower exit guide assembly
6.Remove the sensor/flag assembly from the lower exit guide assembly
Fuser Exit Sensor Flag Assembly
1.Remove the fuser board cover
2.Disconnect the exit sensor from the fuser board.
3.Remove the exit sensor flag assembly.
Note: The exit sensor assembly can be removed without removing the lower exit guide assembly. Make sure the marrow media sensor flag is correctly positioned before snapping the sensor in place.
Fuser Lamp
1.Remove the fuser assembly.
2.Warning: Hold the left lamp bracket and carefully remove the two mounting screws. There is pressure against the other end of the lamp therefore care must be used when removing the lamp from the fuser. Grip the lamp by the ceramic end piece and remove it from the fuser assembly. Be careful not to touch the glass as skin oils and acids can reduce the life of the lamp.
3.Remove the fuser lamp.
Repair Information