The base printer does not recognize that the high capacity input tray is installed.
| FRU | Action |
|
|
|
1 | High Capacity Feeder | Check the high capacity feeder input |
| Autoconnect Mechanical | tray to make sure it is mounted |
| Check | correctly and is not pushed down |
|
| into the frame assembly or |
|
| damaged. Be sure the high capacity |
|
| feeder input tray autoconnect is |
|
| properly connected to the high |
|
| capacity feeder tray option board |
|
| assembly. |
|
|
|
2 | Base Printer or option | Check the option or base printer |
| mounted above | autoconnect for signs of damage. |
|
| Repair the high capacity option |
|
| autoconnect as necessary. |
|
|
|
3 | LVPS | Check the voltages at |
| Option System Board | |
|
| +24 V dc, If the voltage is correct, |
|
| replace the high capacity system |
|
| board assembly. If the voltage is |
|
| incorrect, check the continuity of the |
|
| AC input cable to the LVPS. If |
|
| correct, replace the LVPS assembly. |
|
| If incorrect, replace the AC cable to |
|
| the input of the LVPS. |
|
|
|