4069-XXX

The elevator moves in one direction only.

 

FRU

Action

 

 

 

1

DC Drive Motor

Check the voltages at J1 on the high

 

Assembly High

capacity system board. The voltages

 

Capacity Feeder

measure as follows:

 

System Board

Static (Motor Not Running)

 

 

 

 

J1-1 (Brown): approximately 0 V dc

 

 

J1-2 (yellow): approximately 0V dc

 

 

Motor Running Forward

 

 

J1-1 (Brown): Approximately 0 V dc

 

 

J1-2 (Yellow): Approximately +24V dc

 

 

Motor Running Reverse

 

 

J1-1 (Brown): Approximately +24 V dc

 

 

J1-2 (Yellow): Approximately 0 V dc

 

 

If any of the voltages are incorrect,

 

 

disconnect the motor and measure the

 

 

resistance between J-1 and J-2. The

 

 

resistance measures between 7.5 and 10.5

 

 

ohms. If incorrect replace the motor. If

 

 

correct, replace the system board.

 

 

 

2-64Service Manual

Page 92
Image 92
Lexmark 4069-XXX manual XXX Elevator moves in one direction only