230 Paper Jam - Check Duplex message displays. The page is not duplexed and only exits half way out of the redrive.

 

FRU

Action

 

 

 

1

Duplex Stepper Motor

Check the stepper motor cable for

 

 

cuts or pinched wiring. Check the

 

 

routing of the motor leads along the

 

 

left side of the bottom tray. Check for

 

 

correct installation of the motor cable

 

 

connector at J3 on the system

 

 

board. Check for any shorts between

 

 

each pin of the motor cable and the

 

 

motor housing. If shorts are found,

 

 

replace the motor. Check the

 

 

resistance of the stepper motor

 

 

between J3-1 (Stpmtr A-) to J3-2

 

 

(Stpmtr A+). The resistance

 

 

measures approximately 10 ohms.

 

 

The resistance between J3-3

 

 

(Stpmtr B-) to J3-4 (Stpmtr B+)

 

 

measures approximately 10 ohms. If

 

 

the resistance is incorrect, replace

 

 

the stepper motor. Check for shorts

 

 

between windings on pins J3-1 to

 

 

J3-2 and pins J3-3 to J3-4. If a short

 

 

is found, replace the stepper motor

 

 

assembly. If no short is found,

 

 

replace the duplex system board.

 

 

 