4069-XXX
Cover Open Switch/Cable Service Check
| FRU | Action |
|
|
|
1 | Toner Cartridge | Check the toner cartridge to make |
|
| sure it is correctly installed and that |
|
| the right and left cartridge tracks are |
|
| not loose or broken. Check to make |
|
| sure the cover open switch activation |
|
| tab on the toner cartridge is not |
|
| broken and that the tab correctly |
|
| activates the cover open switch |
|
| spring. |
|
|
|
2 | Cover Open Switch/Cable | Check the cover open switch for |
| Assembly | proper mechanical operation. If |
|
| incorrect, repair as necessary. |
|
| Disconnect the cover open switch |
|
| cable from J4 at the engine board |
|
| and measure the voltage at |
|
| measures approximately +5 V dc. If |
|
| the voltage is incorrect, replace the |
|
| engine board. If the voltage is |
|
| correct, check the voltage at |
|
| the voltage measures greater than |
|
| +1.0 V dc, replace the engine board. |
|
| If the voltage is correct, check the |
|
| continuity between |
|
| the cable. If no change in continuity |
|
| occurs as the switch is activated, |
|
| replace the cover open switch/cable |
|
| assembly. If the continuity changes |
|
| as the switch is activated, replace |
|
| the engine board. |
|
| Note: It is easier to check the |
|
| voltages on J4 with the controller |
|
| board removed. |
|
|
|
Diagnostic Information