4069-XXX

Excessive Noise or Vibration

 

FRU

Action

 

 

 

1

DC Motor Assembly

Check to make sure all the motor

 

 

plate mounting screws are tight.

 

 

 

2

Idler Pulley

Check to make sure the idler pulley

 

DC Motor Assembly

is not binding on the pulley shaft.

 

 

Check the pulley for any signs of

 

 

wear. Check the idler pulley shaft on

 

 

the motor mounting plate for any

 

 

signs of damage or contamination.

 

 

 

3

Drive Pulley

Check the drive pulley for any signs

 

 

of wear, binds or damage to the

 

 

pulley or pulley shaft. Make sure the

 

 

pulley turns freely on the pulley

 

 

shaft.

 

 

 

4

Motor Drive Belt

Check the DC motor drive belt for

 

Tray Drive Belt

any signs of damage. Check to make

 

 

sure the belt is tracking correctly on

 

 

the drive pulley, idler pulley and

 

 

motor pulley. Check the tray drive

 

 

belt for any signs of damage. Check

 

 

to make sure the belt is tracking

 

 

correctly on the lower section of the

 

 

drive pulley and lead screw pulleys.

 

 

 

Diagnostic Information 2-67

Page 95
Image 95
Lexmark 4069-XXX manual XXX Excessive Noise or Vibration