4069-XXX
Excessive Noise or Vibration
| FRU | Action |
|
|
|
1 | DC Motor Assembly | Check to make sure all the motor |
|
| plate mounting screws are tight. |
|
|
|
2 | Idler Pulley | Check to make sure the idler pulley |
| DC Motor Assembly | is not binding on the pulley shaft. |
|
| Check the pulley for any signs of |
|
| wear. Check the idler pulley shaft on |
|
| the motor mounting plate for any |
|
| signs of damage or contamination. |
|
|
|
3 | Drive Pulley | Check the drive pulley for any signs |
|
| of wear, binds or damage to the |
|
| pulley or pulley shaft. Make sure the |
|
| pulley turns freely on the pulley |
|
| shaft. |
|
|
|
4 | Motor Drive Belt | Check the DC motor drive belt for |
| Tray Drive Belt | any signs of damage. Check to make |
|
| sure the belt is tracking correctly on |
|
| the drive pulley, idler pulley and |
|
| motor pulley. Check the tray drive |
|
| belt for any signs of damage. Check |
|
| to make sure the belt is tracking |
|
| correctly on the lower section of the |
|
| drive pulley and lead screw pulleys. |
|
|
|