4069-XXX

 

FRU

Action

 

 

 

4

Motor does not turn, no

Check the voltages at J12 on the

 

gear error code 936 or User

engine board.

 

message 201 Paper Jam

 

 

displays.

Pin number and voltage:

 

 

J12-1 = +24 V dc

 

 

J12-4 = +5 V dc (static) 0 V dc

 

 

(when main drive motor running)

 

 

J12-5 = + 5 V dc (static) 0 V dc

 

 

(when main drive motor running)

 

 

J12-6 = +5 V dc (static) +2.5 V dc

 

 

(when main drive motor running)

 

 

J12-7 = +5 V dc (static) 0 V dc

 

 

(when main drive motor running)

 

 

J12-8 = +5 V dc (static) +5 V dc

 

 

(when main drive motor running)

 

 

J12-11 = + 5 V dc (static) 0 V dc

 

 

(when main drive motor running)

 

 

If the voltage is incorrect, replace the

 

 

FRUs in the following order:

 

 

main drive motor assembly

 

 

engine board

 

 

 

Operator Panel Service Check

Operator Panel Buttons Service Check

Note: Before continuing with this service check do the “Button Test” on page 3-9in the diagnostic aids chapter.

 

FRU

Action

 

 

 

1

Operator Panel Assembly

If any button fails the Button Test,

 

 

replace the operator panel assembly.

 

 

 