4069-XXX
Error Code | Action | |
|
|
|
914 | DC pick | Check the integrated paper tray (tray 1) for correct paper |
motor: No | loading. Reload the paper and POR the printer. If the | |
encoder feedback | error continues, go to the “Input Tray(s) Option Service | |
|
| Check” on page |
|
|
|
917 | Transfer Roll | Indicates a problem in the transfer roll area. Go to the |
|
| “Transfer Roll Service Check” on page |
|
| Note: This error also displays if an incorrect level HVPS |
|
| assembly is installed in a printer that has the erase lamp |
|
| assembly installed. Check to make sure the correct |
|
| HVPS assembly is installed. |
|
|
|
920 | Fuser Error | Indicates that the fuser is below temperature when |
|
| printing. Go to the “Fuser Service Check” on page |
|
|
|
921 | Fuser Error | Indicates that the fuser is below standby temperature |
|
| when the printer is idle. Go to the “Fuser Service Check” |
|
| on page |
|
|
|
922 | Fuser Error | Fuser failed to reach standby temperature. Go to the |
|
| “Fuser Service Check” on page |
|
|
|
923 | Fuser Error | Fuser is too hot during printing or when printer is idle. Go |
|
| to the “Fuser Service Check” on page |
|
|
|
924 | Fuser Error | An open circuit has been detected in the Fuser |
|
| Thermistor Circuit. Go to the “Fuser Service Check” on |
|
| page |
|
|
|
925 | Fuser Error | Wrong fuser lamp installed. Check the fuser lamp for the |
|
| correct type of lamp that should be installed. |
|
| If the correct lamp has been installed and you still have a |
|
| 925 error, the following may be the cause: |
|
| 1. The fuser may have reached standby temperature too |
|
| quickly. |
|
| 2. Check too make sure the correct hot roll has been |
|
| installed. |
|
| 3. Check the line voltage to make sure it is not above the |
|
| maximum rating for the printer. |
|
|
|
927 | Fan Stalled | Indicates a printer fan stalled. Go to the “Fan Service |
|
| Check” on page |
|
|
|
Diagnostic Information