4069-XXX

No indication that Bin X is Full OR No indication that Bin X is Near Full

 

FRU

Action

 

 

 

1

Dual Output Bin X Sensor

Check for correct installation of

 

Assembly

the sensor cable at J5 on the

 

Control Board

control board. If either the Bin Full

 

 

(F) or Bin Near Full (NF) fail the

 

 

sensor test then check the voltage

 

 

at J5-3 and J5-4. The voltage

 

 

measures approximately +5 V dc.

 

 

If the voltage is incorrect, replace

 

 

the control board. If correct,

 

 

replace the sensor assembly.

 

 

 

High-Capacity Output Stacker Service Check

Service Tip: The majority of the mechanical components can be observed during operation by removing the left, right and front covers. The high capacity output stacker option functions without the covers installed.

Models 010 and 010n do not support this output option.

Determine which paper path stacker assembly is not functioning properly.

Make sure the option(s) are installed correctly and the machine is configured correctly before attempting to service the high-capacity output stacker option.

Go to “High-Capacity Output Stacker Board” on page 5-22 to identify the correct jumper location at J6 for the upper and lower units.

Diagnostic Information 2-79

Page 107
Image 107
Lexmark 4069-XXX manual High-Capacity Output Stacker Service Check