4069-XXX
The multipurpose tray and the envelope feeder do not have a paper low sensor. The multipurpose tray does not have a pass through sensor.
Output Bin Test - Standard Bin
This test is used to verify if the standard bin sensor is working correctly.
To run the Standard Bin Sensor Test:
1.Select Output Bin Tests from the Diagnostic Menu.
2.Select Output Bin Tests - Sensor Tests.
3.Select Sensor Tests - Standard Bin.
–“Standard Bin/Full=CL” message displays.
Manually actuate the bin sensor by moving the flag in and out of the sensor. The display indicates OP (open) when the flag is out of the sensor and CL (closed) when the flag is in the sensor.
4. Press Return/Stop to exit the test.
Output Bin Feed Test
Note: If the “Configure Bins” printer setting is link rather than mailbox, the printer selects its own internal bin linking regardless of which output bin is selected for the feed test
This test is to verify that media can be fed to a specific output bin. No information is printed on the media because the printhead is not turned on during this test.
To run the Output Bin Feed Test:
1.Select Feed Test from the Output Bin Test menu.
2.Select the output bin you want the paper to exit into. All output bins installed on the printer are shown on the feed test menu.
3.Select either Single (one sheet of media feeds to the selected output bin) or Continuous (media continues feeding to the selected output bin) until Return/Stop is pressed.
4.Press Return/Stop to exit the test.
Diagnostic Aids