4069-XXX
| FRU | Action |
|
|
|
4 | Operator Panel all | Check to make sure a SIMM is not |
| diamonds, No Beeps | plugged in backward. This condition |
|
| causes the printer to fail POST |
|
| displaying all diamonds on the |
|
| operator panel with no beeps. |
|
|
|
5 | Operator Panel all | Check the voltage at Pin |
| diamonds, 5 Beeps | |
|
| approximately +5 V dc. If incorrect, |
|
| replace the FRUs in the following |
|
| order: |
|
| operator panel assembly |
|
| engine board |
|
|
|
Options Service Check
Service Tip: When you have a problem with any of the options installed in the options slots on the interconnect board on a 212/414/ 616 (the 010 and 010 at service level B have only one slot), switch the non operating option to one of the other option slots to isolate the failure.
Flash Memory Option(s)
Run a copy of the test page and check to see if the option you are checking is listed. The printer does not recognize the option being installed if the option is not listed. Check to make sure that the Memory DIMM is installed correctly and is not broken or damaged. If the Memory DIMM is correctly installed not broken or damaged then run the “Flash Test” on page
DRAM Memory Option(s)
This service check is the same as the flash memory option service check with the following exception:
Run the “SDRAM Memory Test” on page