| FRU | Action |
|
|
|
9 | Engine Board | Turn the printer off and disconnect |
|
| all the cables from the engine board. |
|
| Check for +5 V dc at the engine |
|
| board test point. If incorrect, replace |
|
| the FRUs in the following order: |
|
| engine board |
|
| interconnect board |
|
| If correct, turn the printer off and |
|
| reconnect one cable at a time until |
|
| you find the defective assembly. |
|
| Service Tip: A short or low |
|
| resistance load that is attached to |
|
| the engine board can cause the |
|
| LVPS to overcurrent and shut the |
|
| +5 V dc supply down to 0 V dc. |
|
| Service Tip: Check the engine board |
|
| for burn marks or other damage, |
|
| especially R20,R21, R22 and R23 |
|
| located next to the upper left engine |
|
| board mounting screw. If this screw |
|
| is overtightened it might deform the |
|
| engine board shield and cause it to |
|
| short out these resistors. |
|
|
|