4069-XXX
990 Service - BIN X
| FRU | Action |
|
|
|
1 | D.C. Motor | Check the DC motor cable |
| Mechanical Linkage | connector to be sure it is correctly |
| Assembly | installed at J4 on the output |
|
| expander option board. If correct, |
|
| disconnect J4 from the option |
|
| board and check the resistance of |
|
| the motor on the cable connector: |
|
| |
|
| 115 and 135 ohms. Also check J4- |
|
| 1 and |
|
| shorts. If either the resistance is |
|
| incorrect or a short is found, |
|
| replace the motor/mechanical |
|
| linkage assembly. |
|
| Note: If the DC motor is shorted, it |
|
| may also be necessary to replace |
|
| the control board. |
|
|
|
2 | Output Expander Control | Disconnect the motor cable J4 |
| Board | and check the voltages at J4 on |
|
| the board. |
|
| Note: Use caution not to short to |
|
| adjacent pins on the connector. |
|
| |
|
| |
|
| |
|
| |
|
| If any of the voltages are incorrect, |
|
| replace the control board. If the |
|
| voltages are correct, replace the |
|
| DC motor/mechanical linkage |
|
| assembly. |
|
|
|