Table 6.13 and Figure 6.7 provide Reset Input timing data.

Table 6.13

Reset Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbol

Parameter

 

 

 

 

 

Min

 

 

Max

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t1

Reset pulse width

 

 

 

 

 

10

 

 

 

 

 

tCLK

t2

Reset deasserted setup to CLK HIGH

0

 

 

 

 

 

 

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t3

MAD setup time to CLK HIGH

 

 

 

 

 

20

 

 

 

 

 

ns

 

 

(for configuring the MAD bus only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t4

MAD hold time from CLK HIGH

 

 

 

 

 

20

 

 

 

 

 

ns

 

 

(for configuring the MAD bus only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6.7

Reset Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

t2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RST/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAD1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t3

 

t4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valid Data

 

 

 

 

Note:

1. When enabled.

 

Table 6.14 and Figure 6.8 provide Interrupt Output timing data.

 

Table 6.14

Interrupt Output

 

 

 

 

 

 

 

 

Symbol

Parameter

Min

Max

Unit

 

 

 

 

 

t1

CLK HIGH to IRQ/ LOW

2

11

ns

 

 

 

 

 

t2

CLK HIGH to IRQ/ HIGH

2

11

ns

 

 

 

 

 

t3

IRQ/ deassertion time

3

CLK

6-10

Electrical Specifications

Page 248
Image 248
LSI 53C875A technical manual Reset Input, Interrupt Output