RST

SCSI Reset Condition

1

 

Indicates assertion of the SRST/ signal by the

 

 

LSI53C875A or any other SCSI device. This condition is

 

edge-triggered, so multiple interrupts cannot occur

 

 

because of a single SRST/ pulse.

 

PARSCSI Parity Error0

Indicates detection by the LSI53C875A of a parity error while receiving or sending SCSI data. See the Disable Halt on Parity Error or SATN/ Condition bits in the SCSI Control One (SCNTL1) register for more information on when this condition is actually raised.

Register: 0x41

SCSI Interrupt Enable One (SIEN1)

Read/Write

7

 

 

 

3

2

1

0

 

 

R

 

 

STO

GEN

HTH

x

x

x

x

x

0

0

0

 

 

 

 

 

 

 

 

This register contains the interrupt mask bits corresponding to the interrupting conditions described in the SCSI Interrupt Status One (SIST1) register. An interrupt is masked by clearing the appropriate mask bit. For more information on interrupts, refer to Chapter 2, “Functional Description.”

R

Reserved

[7:3]

STO

Selection or Reselection Time-out

2

 

The SCSI device which the LSI53C875A is attempting to

 

select or reselect does not respond within the

 

 

programmed time-out period. See the description of the

 

SCSI Timer Zero (STIME0) register bits [3:0] for more

 

information on the time-out timer.

 

GEN

General Purpose Timer Expired

1

 

The general purpose timer is expired. The time measured

 

is the time between enabling and disabling of the timer.

 

See the description of the SCSI Timer One (STIME1)

 

register, bits [3:0], for more information on the general

 

purpose timer.

 

SCSI Registers

4-75

Page 167
Image 167